Field-Programmable Gate Arrays

15255 Threads Posts
to

Nios Development Kit, STRATIX Edition

Hey Guys, I have this "development Suite" and am wondering if it is worth anything, I'd like to sell it. If it isn't I'...
1 comments posted 22yrs
posted by yudhvir
1 comments posted 22yrs posted by yudhvir

Counter counting on both clock edges.

I'm trying to produce a square wave clock that is a fifth of the frequency of a faster clock. This means that I must us...
15 comments posted 22yrs
posted by andrew
15 comments posted 22yrs posted by andrew

SOC and ASIC ?

Hi, Can any help me out to understand, how does SOC differs from ASIC ? -Muthu.
3 comments posted 22yrs
posted by muthusnv
3 comments posted 22yrs posted by muthusnv

PLB above 100MHz ?

Hi ! According to Xilinx documentations, the PLB bus is limited to 100MHz. We have a need to run at higher frequencies,...
0 comments posted 22yrs
posted by russelmann
0 comments posted 22yrs posted by russelmann

16-depth FIFO and 64-depth FIFO use the same Ram

Hi, I generated two FIFOs using Xilinx ISE CoreGen. Both FIFOs are 64-bit wide, but one FIFO depth is 16, the other is...
2 comments posted 22yrs
posted by bonetiger_1984
2 comments posted 22yrs posted by bonetiger_1984

Problems With Spartan 3 Starter Board

Using the Xilinx-supplied .mcs files I can program the configuration PROM and run these reference designs: "Default Boa...
1 comments posted 22yrs
posted by apple2ebeige
1 comments posted 22yrs posted by apple2ebeige

Channel Link signals into Xilinx

Does anyone here have experience transmitting and receiving Channel Link or Camera Link signals directly into a Virtex...
3 comments posted 22yrs
posted by bradsmallridge
3 comments posted 22yrs posted by bradsmallridge

using GNU to compile for PPC405?

Has anybody out there had any luck using GNU tools to compile source code into an ELF file that can be loaded into an IS...
3 comments posted 22yrs
posted by mer2
3 comments posted 22yrs posted by mer2

Xilinx Spartan 3 DCM/DFS

I noticed that for Spartan 3 the DCM status does not define bit 2 any more. In Virtex II it meant that the DFS was stop...
1 comments posted 22yrs
posted by tony.casorso
1 comments posted 22yrs posted by tony.casorso

Impact vs. Linux RedHat Linux

I filed a WebCase over this, but I'm going to ask here in case others have run into this problem as well. I expect the...
8 comments posted 22yrs
posted by spamtrap
8 comments posted 22yrs posted by spamtrap

How to Figure out EPLD can be socketed or not!

Helo Guys, I am sort of new to it. I need to buy some EPLD which can be socketed so that I can remove and put another o...
2 comments posted 22yrs
posted by dhruvish
2 comments posted 22yrs posted by dhruvish

FPGA Board Newsletter August 2004

FPGA Board Newsletter August 2004 BurchED - Making FPGA Prototyping Easy! http://www.burched.biz In this newsletter: (1...
0 comments posted 22yrs
posted by tony
0 comments posted 22yrs posted by tony