Aug 27, 2004 1 Replies

I noticed that for Spartan 3 the DCM status does not define bit 2 any more. In Virtex II it meant that the DFS was stopped. Does this mean the DFS never stops? I want to use DFS mode (no CLKFB). How do I know if I need to reset the DCM?



Thanks,



Tony


STATUS[2] is still the "CLKFX or CLKFX180 Output Stopped Indicator", as shown in XAPP462.

formatting link

I see, however, that it's missing from the latest data sheet! I'll file a bug report.

--------------------------------- Steven K. Knapp Applications Manager, Xilinx Inc. General Products Division Spartan-3/II/IIE FPGAs

formatting link

--------------------------------- Spartan-3: Make it Your ASIC