Field-Programmable Gate Arrays

15255 Threads Posts
to

Why is router software not multi-threaded?

Excuse my ignorance if there is an obvious answer ... Is it true that the routing algorithms used in Altera's and Xilin...
5 comments posted 22yrs
posted by petersommerfeld
5 comments posted 22yrs posted by petersommerfeld

systemc download page?

Hi, I tried to register at www.systemc.org . There is no email to confirm . Does all the OSCI members delete the O in th...
1 comments posted 22yrs
posted by tirmen
1 comments posted 22yrs posted by tirmen

Post-Place & Route simulation with MicroBlaze

Hi all, I have a design where MicroBlaze isn't the top level of it. I have simulated the behavioral model with ModelSim...
4 comments posted 22yrs
posted by arkagaz
4 comments posted 22yrs posted by arkagaz

Virtex II Pro, powerpc 405 and ucOSII

Hi, Is there anybody ou there who tried to run the real time OS ucOSII on a virtex II platform ? Have you tried differe...
0 comments posted 22yrs
posted by nospam
0 comments posted 22yrs posted by nospam

Verilog 2001 indexed part select in XST 6.1.3?

Hi, Does anyone know if XST 6.1.3 supports the "indexed part select" feature of Verilog 2001? (It's in section 4.2.1 of...
2 comments posted 22yrs
posted by allan.herriman.hates.spam
2 comments posted 22yrs posted by allan.herriman.hates.spam

Xilinx old development tool

Hi, I have to modify an hold XC3042 project, developed in 1993 using XACT 4.12. Actually I have only the LCA design fil...
0 comments posted 22yrs
posted by claudio.tavoni
0 comments posted 22yrs posted by claudio.tavoni

Synthesis errors?

Hi, I have recently had lots of incorrectly synthesised logic with the synthesiser I am using. My latest design occupie...
3 comments posted 22yrs
posted by junk
3 comments posted 22yrs posted by junk

map gives yet another error!

I get the following error while doing map on my design -------------------------------------------------------------- t...
1 comments posted 22yrs
posted by nachikap
1 comments posted 22yrs posted by nachikap

Soft failures (?) 9536XL

I have a small circuit using the 9536XL CPLD. The complete machine uses 64 of such circuits. I have tested it on the la...
9 comments posted 22yrs
posted by j.duran
9 comments posted 22yrs posted by j.duran

MACH5 eval board - doc needed

I am looking for documentation for a MACH 5 evaluation/demo board I have. This board was made by AMD. The only printing...
0 comments posted 22yrs
posted by widlicka
0 comments posted 22yrs posted by widlicka

xilinx 70% tracking rule

Hi there, Sorry for another Xilinx-specific question :) Peter Alfke mentioned this 70% tracking rule for timing paramet...
13 comments posted 22yrs
posted by guillerodriguez
13 comments posted 22yrs posted by guillerodriguez

EDK - Desinging system with C++

Hi Group Members, Xilinx claims it supports C++ system design(s/w part ) with EDK tool kit. I am having virtex 2 pro bo...
0 comments posted 22yrs
posted by ramntn
0 comments posted 22yrs posted by ramntn

How can I have multiple drivers of one inout port?

Hi, I am trying to connect the bidirectional ports of two components to one bidirectional set of pins on my FPGA. Is it...
1 comments posted 22yrs
posted by cruiser144
1 comments posted 22yrs posted by cruiser144