Hello,
has anybody experiences with the seyon terminal in connection with u-boot. Occurs with seyon also problems with the serial download or exists other known problems.
Thanks in advance Bernhard
Hello,
has anybody experiences with the seyon terminal in connection with u-boot. Occurs with seyon also problems with the serial download or exists other known problems.
Thanks in advance Bernhard
AFAIK seyon does NOT work with s-record download (loads command), and does not implement kermit binray protocol, so you cannot use the lodb command either. I recommend to stick with the documented tools ("cu" for loads and "kermit" for loadb).
See also:
Best regards,
Wolfgang Denk
-- Software Engineering: Embedded and Realtime Systems, Embedded Linux Phone: (+49)-8142-4596-87 Fax: (+49)-8142-4596-88 Web: www.denx.de