Field-Programmable Gate Arrays

15255 Threads Posts
to

Simulating multi-chip design

I am working on a design involving 2 4028EX devices along with an external SRAM bank. Is there a way I can simulate bot...
1 comments posted 22yrs
posted by no
1 comments posted 22yrs posted by no

readback spartan2e

I am working with a spartan2e and i wish readback the register, not my configuration, i read that is posible, i am usin...
1 comments posted 22yrs
posted by silviai
1 comments posted 22yrs posted by silviai

VirtexE DLL locked range

Xilinx claimed that VirtexE DLL locks with input range 60-130 MHZ, my question is what's output clock limitation? Suppos...
1 comments posted 22yrs
posted by
1 comments posted 22yrs posted by

Xilinx Virtex II Output Register

I have a input signal thats get registered and then outputed on another signal (pad) One register delay. I would like t...
2 comments posted 22yrs
posted by jcocozza
2 comments posted 22yrs posted by jcocozza

Questions about guard bits in CORDIC algorithm

Hi, I have learned about CORDIC from this group, especially from Ray. Now, I have several more questions. One paper des...
4 comments posted 22yrs
posted by freelait2000
4 comments posted 22yrs posted by freelait2000

Installation of Xlinx

Hi, I have just installed Xilinx5.1i on a pc running Win2000 with SP4. After the installation and reboot the machine, t...
2 comments posted 22yrs
posted by renping.liu
2 comments posted 22yrs posted by renping.liu

XST cant compile with blaxkboxes.

Hi, there: I am using ISE6.1 in office and ISE6.1Webpack at home. Both have service park 3 I think. How come on Webpack...
2 comments posted 22yrs
posted by kelvin8157
2 comments posted 22yrs posted by kelvin8157

Followup to those that downloaded SeaHDL/SimHDL

Hello to the folks that downloaded SeaHDL/SimHDL from http://etherdesign.tripod.com. Please tell me your first impressi...
0 comments posted 22yrs
posted by joe
0 comments posted 22yrs posted by joe

fast mod (remainder) algorithm for V2?

I'm looking for a fast integer mod routine to be executed on a Virtex2-6000. Let's say 256bit unsigned integer divided...
2 comments posted 22yrs
posted by bking
2 comments posted 22yrs posted by bking

v2px70 available?

Hi, are they shipping? Thomas
0 comments posted 22yrs
posted by tirmen
0 comments posted 22yrs posted by tirmen

Altera CPLD - Illegal assignment-global clock

Newbie I try to use an Altera CPLD EPM7064. When I try to connect a register clock input to a normal pin, I get the mes...
2 comments posted 22yrs
posted by no_spam
2 comments posted 22yrs posted by no_spam