EDK question

Hi everybody,

I am using PPC to configure number of LUTs using HWICAP, my question is , Is it possible to generate an interrupt internally according to a change in register value , as i want to do new configuration depending on this value?

thanks Fatma

Reply to
fmostafa
Loading thread data ...

Register internal to the CPU or hardware register. What device are you using?

---Matthew Hicks

Reply to
Matthew Hicks

my device is xc2vp30

Reply to
fmostafa

Then you are using a version of the PPC405 that doesn't support a coprocessor so there is no way to know the instantaneous value of internal registers.

---Matthew Hicks

Reply to
Matthew Hicks