Field-Programmable Gate Arrays

15255 Threads Posts
to

Spartan 3 termination question (DCI)

I'm looking at the DCI (digitally controlled impedance) part of the Spartan-3 spec, and I'm wondering if I can use this...
29 comments posted 22yrs
posted by danielgk
29 comments posted 22yrs posted by danielgk

Pre-PhD fellowship

SmartLab Dept. of Biophysical and Electronic Engineering University of Genoa, Italy is offering TWO short-term research...
0 comments posted 22yrs
posted by anguita
0 comments posted 22yrs posted by anguita

Virtex II Pro - Frame Addressing

hi I have some problems with frame address calculation for readback on Xilinx Virtex II Pro XC2VP7. This is what I know...
0 comments posted 22yrs
posted by andreasweder
0 comments posted 22yrs posted by andreasweder

Icarus Verilog for Windows

Hello people. I will be maintaining recent snapshots of the Icarus Verilog compiler for the Windows platform in easy to...
3 comments posted 22yrs
posted by pablobleyer
3 comments posted 22yrs posted by pablobleyer

configuration for a mixed mode VHDL-verilog lang

Hi all My problem is I'd like to choose a VHDL file instantiated inside verilog via VHDL configuration To summerize: I...
0 comments posted 22yrs
posted by rakesh_yc
0 comments posted 22yrs posted by rakesh_yc

EDA apps on Mac OSX?

OSX is basically FreeBSD unix under the hood with a very nice GUI. Given the fact that dual processor G5's are essentia...
0 comments posted 22yrs
posted by ptkwt
0 comments posted 22yrs posted by ptkwt

Xilinx Student Foundation Edition on Windows-XP ??

We have been using Xilinx Student Edition 2.1i in a Third World university for several years. Now that we have upgraded...
5 comments posted 22yrs
posted by petrapam1943
5 comments posted 22yrs posted by petrapam1943

programming to simulatin

We have some programming files (we have rights to the source, and have hardcopy of the source in schematics, no softcop...
1 comments posted 22yrs
posted by fskalka
1 comments posted 22yrs posted by fskalka

extending a signal pulse

Hi all, What would be the optimal way, in terms of device utilization and=20 functionality, to exstend the length of th...
3 comments posted 22yrs
posted by xjohbex
3 comments posted 22yrs posted by xjohbex

runing a bootloader on a Virtex II Pro Board???

Hello, I built my design with EDK (using BSB base system builder), I generated my xparameters.h I compiled U-boot (the...
0 comments posted 22yrs
posted by abdelmajid.bouajila
0 comments posted 22yrs posted by abdelmajid.bouajila

How to constrain a divide by 3 clock?

Hi, there: My clk_4m is generated from clk_12m through a divide_by_3 state machine... And I feed clk_4m into a BUFG als...
2 comments posted 22yrs
posted by student
2 comments posted 22yrs posted by student

Nios - Ethernet Frame Format

Hi, I would like to know if the Ethernet packets sent through the Nios Ethernet Kit, do they have a 32-bit CRC as the t...
4 comments posted 22yrs
posted by csim036
4 comments posted 22yrs posted by csim036

false paths, Synplify

Hello, How does one specify ANY arbitrary path in the design as a false path, using define_false_path in Synplify? defi...
0 comments posted 22yrs
posted by hadley
0 comments posted 22yrs posted by hadley

Chipscope inserter changes net names.

Hi All, When I probe nets with Chipscope Inserter, the net names change. For example, 'clock_enable' changes to 'ila0_t...
0 comments posted 22yrs
posted by symon_brewer
0 comments posted 22yrs posted by symon_brewer