Field-Programmable Gate Arrays

15255 Threads Posts
to

Enum type as array range

Maybe I am being a little dense, but I can't find anything on this in my VHDL books and the LRM is pretty esoteric in t...
2 comments posted 22yrs
posted by spamgoeshere4
2 comments posted 22yrs posted by spamgoeshere4

extending a signal pulse

You could use a SRL16/DFF (with clock-enable and synchronous clear) combination for this. The input pulse - which is hi...
1 comments posted 22yrs
posted by guy.eschemann
1 comments posted 22yrs posted by guy.eschemann

Nios SDK - understanding nm output

Where can I find an explanation of the prefix codes in an nm generated symbol table? I see entries such as 'F' which are...
1 comments posted 22yrs
posted by tns1
1 comments posted 22yrs posted by tns1

Xilinx Virtex-II Configuration in Slave Serial

Hi I want to configure my Virtex-II (Avnet Development Board)using MultiLINX download Cable. I am using Slave Serial Mo...
2 comments posted 22yrs
posted by lists_shehzad
2 comments posted 22yrs posted by lists_shehzad

High Temperature FPGAs

Last year there was a thread here about using FPGAs at high temperatures with limited life. Makmorbi said: I am about t...
0 comments posted 22yrs
posted by keithw
0 comments posted 22yrs posted by keithw

Quartus SOPC Builder doesnt Recgnize my .elf file

Hi, I am using Excalibuer FPGA with ARM 922T I need to download my Digital Design and My Embedded Code on to the chip f...
0 comments posted 22yrs
posted by arasquinha
0 comments posted 22yrs posted by arasquinha

mcu vs fpga help me to choose !!

hello am an mcu developper on 8051 .  never use xilinx fpga wana build an application and i don't know if an fp...
3 comments posted 22yrs
posted by sudrienet
3 comments posted 22yrs posted by sudrienet

WinCUPL state machine for 16V8

I guess the combination of Wincupl and a 16V8 will be pretty much steam technology for most of you but it is a real mys...
7 comments posted 22yrs
posted by peter_harrison
7 comments posted 22yrs posted by peter_harrison

synchronus reset on bufg? (xilinx)

Hey all, I have a synchronus reset signal that has a very large fanout. Is it advisable to put this signal on a bufg? Th...
1 comments posted 22yrs
posted by mer2
1 comments posted 22yrs posted by mer2

micron sdram module

Hi, still sticked in the sdram controller project. I use a micron 256mb sdram following is its datasheet and simulation...
5 comments posted 22yrs
posted by dxslyz
5 comments posted 22yrs posted by dxslyz

Xilinx Virtex 4

Hi, does anybody know if the Virtex 4 family still has some dynamic partial reconfiguration capability? I haven't found...
5 comments posted 22yrs
posted by no_reply
5 comments posted 22yrs posted by no_reply

Altera SOPC SDRAM & CLK Input?

To all, With the help of some of the newsgroup members (thanks alot) I have been able to generate a sopc design with a...
5 comments posted 22yrs
posted by pinod01
5 comments posted 22yrs posted by pinod01

Hazard Analysis ???

Hello, Even the 2:1 Mux has static hazard if we consider all the gates are unit delay elements. Hence do we need to do...
0 comments posted 22yrs
posted by muthusnv
0 comments posted 22yrs posted by muthusnv

KCPSM3+vhdl+verilog

Hi, I am having a problem during the synthesis (with ISE) of my design, with the following error message : "ERROR:HDLCo...
2 comments posted 22yrs
posted by nicolas.farrugia
2 comments posted 22yrs posted by nicolas.farrugia