Field-Programmable Gate Arrays

15255 Threads Posts
to

Quartus Signal Tap problem

I am trying to use Signal Tap with a Cyclone. I have added nodes and set trigger conditions, data enable, compiled, etc...
0 comments posted 21yrs
posted by dsp
0 comments posted 21yrs posted by dsp

Simulation error with ModelSim

hi, I'm using ISE6.3.03i and ModelSim5.6. I have a disign whitch work in simulation "Post Translate" and "Post Map". Bu...
1 comments posted 21yrs
posted by clehobey
1 comments posted 21yrs posted by clehobey

SystemACE and Jtag

I'm working on a Xilinx demonstration board equipped with a jtag chain including a SystemACE CF and a Virtex-II FPGA. M...
2 comments posted 21yrs
posted by scarex_s
2 comments posted 21yrs posted by scarex_s

Asic prototyping in Fpga - prototyping the gates.

Hi, We are currently using virtexIIpro and virtex4 fpga to prototype a dsp processor. All the code is synthesizable ver...
7 comments posted 21yrs
posted by david.lamb
7 comments posted 21yrs posted by david.lamb

Xilinx constraint question- DC input

Hi- I need to add something to my UCF file and I am not entirely sure how to do it. We have a chip that is going to ope...
1 comments posted 21yrs
posted by wpiman
1 comments posted 21yrs posted by wpiman

X-checker Pod : Problem w/ X-checker and Win2000

Hi all, I have a legacy design for an XC4000 that I'm trying to program through the X-checker pod, and this has not wor...
3 comments posted 21yrs
posted by vaynerma
3 comments posted 21yrs posted by vaynerma

Re: C programmer, what does this syntax mean?

Which part, in particular, is confusing? "BluetoothReceiver::BluetoothReceiver() : bandpassFilter(BPLENGTH), differenti...
4 comments posted 21yrs
posted by pdstroud
4 comments posted 21yrs posted by pdstroud

Altera HardCopy and SEUs

Compared with a normal Stratix, is a HardCopy version immune to SEUs? I'd have thought the possibility of a configurati...
7 comments posted 21yrs
posted by rogerwilson
7 comments posted 21yrs posted by rogerwilson

Asynchronous memory in Stratix devices

What if i design an asynchronous memory in Stratix devices?? Will it create any design problems??
1 comments posted 21yrs
posted by bajajk
1 comments posted 21yrs posted by bajajk

Quartus II v4.2 LogicLock Regions

I am trying to get a simple LogicLock region (about 200 LEs) optimized, back annotated and tested. But I am having prob...
1 comments posted 21yrs
posted by djsykoraNOSPAMM
1 comments posted 21yrs posted by djsykoraNOSPAMM

Very Stupid XST verilog synthesis question...

OK. I'm just braindead, my verilog is horribly rusty, insert tons o excuses here, but... I'm struggling with how the in...
4 comments posted 21yrs
posted by nweaver
4 comments posted 21yrs posted by nweaver

jvm on microblaze

hi all, exist a one jvm for the object architecture? thanks risc
0 comments posted 21yrs
posted by opb
0 comments posted 21yrs posted by opb

LVDS through connectors

Hi all, I'm designing a system in which a 4-bit + clock LVDS point-to-point bus has to connect two FPGAs. The two FPGAs...
16 comments posted 21yrs
posted by gbH8SPAM
16 comments posted 21yrs posted by gbH8SPAM