Stratix & PLL

Nov 14, 2003 1 Replies

Hello,



I have a problem with Stratix's PLLs. I want to feed input of Enhanced PLL from Fast PLL and Enhanced PLL form Enhanced PLL.



CLK input -> Fast PLL -> Enhanced PLL -> PLL output -> other logic or CLK input -> Enhanced PLL -> Enhanced PLL -> PLL output -> other logic



Is this two configuration possible to achieve in EP1S25 device?



Quartus 3 signalize errors when I am trying to do that: "Error: inclk0 port of PLL interface_block_hes:INB|hes_plla:u2|altpll:altpll_component|pll must be driven by a non-inverted input pin or, in a fast PLL, the output of a PLL".



Regards, Krzysiek


Hi Krysztof,

The connections described in your post are not possible with the Stratix architecture.

- Subroto Datta Altera Corp.

PLL".

Join the Discussion

Have something to add? Share your thoughts — no account required.

Didn't find your answer?

Ask the community — no account required