Hi,I have a problem that i can't use ISE4.2 download design in CPLD or FPGA with win2000 SP4 system.The iMPACT of ISE4.2 accessories can't find the download cable.I think this is the software problem,because with ISE6.2 all is OK.What is the solution of confict between ISE4.2 and win2000 SP4.
Conflicts between ISE4.2 and win2000 SP4
Jan 12, 2006
6 Replies
It was a long time ago, but I think Xilinx told me to download an earlier version of iMPACT. I only had a problem with CPLDs, IIRC. It found the cable OK, but they wouldn't program.
Leon
Thank for ur suggests,Is there independent Impact for download and what the Impact version u used?
If ISE6.2 works, why do you need to use 4.2? I can understand the need to compile with an earlier version, but why do you need to download with an earlier version?
Alan Nishioka
Release version 4.2i Application version E.35
I don't recall exactly where it came from: possibly one of the Xilinx FAE's on this group can help?
I have solve this problem,the most important is a system file named windrvr.sys.When this file version is 6.03,the impact doesn't work correctly in win2000 sp4,but the version is 5.05,all is ok.
Join the Discussion
Have something to add? Share your thoughts — no account required.
Didn't find your answer?
Ask the community — no account required