FR4 delay tempco

I measured a slab of copperclad FR4 as having a capacitance tempco around +900 PPM/degC. I wonder what would be the temperature coefficient of delay for a microstrip or stripline on FR4. Not only does the dielectric constant change, but a board will expand in x/y/z too.

I guess I could measure it, which could be a nuisance.

--
John Larkin         Highland Technology, Inc 
picosecond timing   precision measurement  
 Click to see the full signature
Reply to
John Larkin
Loading thread data ...

To leading order, the effective epsilon of microstrip is (1+eps_FR4)/2. Delay is approximately proportional to the square root of that (i.e. the refractive index n), so one expects that

n ~ sqrt((1+eps))/2

You can obviously do that out at length, but for SWAG purposes, it's easier to do it numerically, with eps = 4 and d/dT(eps) = 0.0036/K.

sqrt((1+4.0036)/2)/sqrt((1+4)/2)-1 = 0.00036, i.e. 360 ppm/K.

The in-plane thermal expansion coefficient is less than this, so at this accuracy level it can probably be ignored.

Cheers

Phil Hobbs

--
Dr Philip C D Hobbs 
Principal Consultant 
 Click to see the full signature
Reply to
Phil Hobbs

Yeah, I guess the dimensional changes will be small compared to Er.

We're designing a test board for a picosecond instrument. If we match trace lengths to, say, 200 ps, 360 PPM of that is pretty small.

--
John Larkin         Highland Technology, Inc 
picosecond timing   precision measurement  
 Click to see the full signature
Reply to
John Larkin

I just measured one the other day. I got 75% of that value. Nice approximation.

--
Best Regards, 

ChesterW 
 Click to see the full signature
Reply to
ChesterW

Thanks, it's good to pass the sanity check at least occasionally. ;)

Cheers

Phil Hobbs

--
Dr Philip C D Hobbs 
Principal Consultant 
 Click to see the full signature
Reply to
Phil Hobbs