General Electronics

5208 Threads Posts
to

60Vdc supply to 5V regulated?

Any suggestions for voltage regulation from 60Vdc to 5Vdc, LOW current (microcontroller/ADC) thanks
2 comments posted 21yrs
posted by jim22
2 comments posted 21yrs posted by jim22

Need a 24V AC power supply, 850mA

Firstly, I know nothing about electronics so please forgive me if this post in not appropriate in this newsgroup. I nee...
4 comments posted 21yrs
posted by metaphorng
4 comments posted 21yrs posted by metaphorng

110VAC Thermostat danger?

Over on this thread about remote sensor thermostats for fish tanks (the kind designed to switch on and off a resistive...
2 comments posted 21yrs
posted by tylernt
2 comments posted 21yrs posted by tylernt

Solenoid controlled valve

I have an injection molding machine with the following faulty solenoid controlled valve and I wanted to know if it can...
4 comments posted 21yrs
posted by jamesp010
4 comments posted 21yrs posted by jamesp010

Quadravox QV356M4 sound board problems

Hi everybody I have this QV356M4 sound board for a robotics project, and I try t load my own sounds into the board. I u...
0 comments posted 21yrs
posted by alexe_ene
0 comments posted 21yrs posted by alexe_ene

Source control logic vs. Sink control logic?

Hi I have been reading some manuals for different AC and DC drives. Al of them seem to always have digital inputs which...
2 comments posted 21yrs
posted by pwk
2 comments posted 21yrs posted by pwk

Choosing correct phone cable for a new house

My friend is having his house rebuilt. Before the drywall gets pu up, he wants to run phone wires. We are trying to fig...
4 comments posted 21yrs
posted by pwk
4 comments posted 21yrs posted by pwk

Isolating PFC

H I currently Have an applicating which ideally requires a 1KW isolate output at around 350VDC, without having the bulk...
1 comments posted 21yrs
posted by andy.watts
1 comments posted 21yrs posted by andy.watts

SM55 stepper motor

can anyone plz tell me how to use the Fuji SM55 stepper motor? Wher can I find its data sheet
0 comments posted 21yrs
posted by u2003173
0 comments posted 21yrs posted by u2003173

Help, 12vdc to 9vdc

I need to convert 12vdc to 9vdc the simplest way possable, the 9vd load is only 10mA and is constant, is there a quick w...
5 comments posted 21yrs
posted by robertliebnosr
5 comments posted 21yrs posted by robertliebnosr

Quiet UPS?

If anyone knows of more relevant newsgroups to post this to, we'd appreciate the info. We're trying to find an uninterr...
16 comments posted 21yrs
posted by nospam
16 comments posted 21yrs posted by nospam

D type connectors

Hi all, trying to find a source for 19way D-dype male connectors, tried everywhere I can think of any everywhere I can...
11 comments posted 21yrs
posted by exxos
11 comments posted 21yrs posted by exxos

Dc motor voltage rating

What would happen if I had a motor that has markings saying it is a 2.25 hp motor, 130 volt, 18 amp and I pulsed it wit...
11 comments posted 21yrs
posted by pwalinsky
11 comments posted 21yrs posted by pwalinsky