Field-Programmable Gate Arrays

15255 Threads Posts
to

BUFT resources in Spartan II

Hi ! In the spartan datasheet I can read that: "Horizontal routing resources are provided for on-chip 3-state busses. F...
2 comments posted 22yrs
posted by czajnik
2 comments posted 22yrs posted by czajnik

Too many signals [Xilinx Foundation 4.1i]

Hi all,=20 I'd like to highlight a problem encountered while using the Xilinx = foundation series 4.1i. I am unable to...
5 comments posted 22yrs
posted by EBEPriyanto
5 comments posted 22yrs posted by EBEPriyanto

Q:Altera's excalibur device

Dear all, I implement a DMA controller in the PLD side of the ALtera's excalibur device(epxa1), and a block ram in the...
3 comments posted 22yrs
posted by algous2002
3 comments posted 22yrs posted by algous2002

Hold violations

Hi, I have an Altera FPGA, which shows hold violation on an input pin. The first FLOP is positive edge triggered and in...
1 comments posted 22yrs
posted by shardendu
1 comments posted 22yrs posted by shardendu

USB basic doubts

Can somebody help me in understanding few USB related queries? What is USB host controller? What is USB device controll...
2 comments posted 22yrs
posted by dathathreya.bhat
2 comments posted 22yrs posted by dathathreya.bhat

Finding Multicyle Paths in a Design

Hi, Is there any script kind of, which can scan the RTL files and list out the Available Multicyle paths ? It is possibl...
2 comments posted 22yrs
posted by muthu_nano
2 comments posted 22yrs posted by muthu_nano

clock recovery from HDB3 data

hi all, I have a 2.048 Mbps HDB3 data stream, now i should recover the clock from this data stream. For this i am using...
1 comments posted 22yrs
posted by praveen
1 comments posted 22yrs posted by praveen

Quartus-II question

Hi, I am trying to use AVRCore project from opencores.com on ACEX1K100-3 FPGA. Timing summary tells me that maximum clo...
4 comments posted 22yrs
posted by pratipm_nooospam
4 comments posted 22yrs posted by pratipm_nooospam

Skew between the output of a DCM ?

Hi, I remember reading a few lines on this newsgroup about the fact that a DLL in a Virtex might not be able to handle...
4 comments posted 22yrs
posted by jfhasson
4 comments posted 22yrs posted by jfhasson

NIOS: Running code from flash

Is it possible to run nios code from flash memory directly (assuming I'm running at only 10MHz)? Or do I need a small b...
8 comments posted 22yrs
posted by newsmailcomp6
8 comments posted 22yrs posted by newsmailcomp6

How to assign inferred logic to resource in Quartus

Hi, I have a chain of registers to delay a certain wide signal 5 clocks. Quartus infers altshifttaps from this, which i...
2 comments posted 22yrs
posted by cruiser144
2 comments posted 22yrs posted by cruiser144

Verilog-2001 `define expressions?

I was trying to use a macro 'expression' -- `define MAXIMUM2( x, y ) ( ((x)>(y))?(x):(y) ) // return greater value para...
2 comments posted 22yrs
posted by toby
2 comments posted 22yrs posted by toby

MicroBlaze - how much memory?

Hi! How much extra RAM (additional to the pure code size of the user program) do I usually need for a MicroBlaze system...
1 comments posted 22yrs
posted by RISC_taker
1 comments posted 22yrs posted by RISC_taker