Field-Programmable Gate Arrays

15255 Threads Posts
to

newbie question: speed grade + area constraint

this might be a stupid question, but what does a speedgrade actually mean? i haven't found a clear and short answer yet...
1 comments posted 22yrs
posted by Yttrium
1 comments posted 22yrs posted by Yttrium

Tutorials for ISE and Quartus

I've posted 2 (very graphical) tutorial for ISE and Quartus. ISE: http://www.fpga4fun.com/ISEQuickStart.html Quartus: h...
1 comments posted 22yrs
posted by j.nicolle
1 comments posted 22yrs posted by j.nicolle

Synthesis in VHDL vs. Verilog

Greetings: I am reading J Bhasker's "Verilog HDL Synthesis" along with "A Verilog Primer" in order to learn not only Ve...
28 comments posted 22yrs
posted by crcarle
28 comments posted 22yrs posted by crcarle

DPRAM using the CoreGenerator, VHDL-example

Hello, I'm using Xilinx ISE 6.1. I'm using the CoreGenerator for designing a dual port RAM (block RAM). Is there an exa...
2 comments posted 22yrs
posted by Tobias.Moeglich
2 comments posted 22yrs posted by Tobias.Moeglich

plb_sdram, timing error

Hello (world), I've a dodgy problem with a plb_sdram_v1_00_c connected to the PLB with a PowerPC as single master and a...
0 comments posted 22yrs
posted by nospams
0 comments posted 22yrs posted by nospams

Xilinx Question

hi , basic question on the free xilinx tools you can download from the web ( may be designing for spartan ) i thought ,...
2 comments posted 22yrs
posted by stanandsue2000REMOVE
2 comments posted 22yrs posted by stanandsue2000REMOVE

Clock domains

Hi, I have two clock domains in my Verilog design (Spartan2), 33 MHz and 20 MHz. My problem: data transport between dom...
2 comments posted 22yrs
posted by bereg
2 comments posted 22yrs posted by bereg

IP or Core

Hi, Are there any difference between "CORE" and "IP"? (thinking terminology) Thanks for you advice Laurent www.amontec....
1 comments posted 22yrs
posted by laurent.gauch
1 comments posted 22yrs posted by laurent.gauch

SDRAM Controller timing problem

Hello, I have implemented my own SDRAM controller in a Virtex II component in order to use SDRAM modules Sodimm-PC133 (...
10 comments posted 22yrs
posted by etraq
10 comments posted 22yrs posted by etraq

Re: How do you initialize signals in VHDL?

If your synthesis tool creates FFs that power up as zero, by default, then you could try this: process(clk) begin if ris...
0 comments posted 22yrs
posted by a
0 comments posted 22yrs posted by a

Generate the first interrupt for MB XMK

Hi! My question is long, but bare with me. I am using EDK 3.2 and trying to get Microblaze XMK working from external me...
2 comments posted 22yrs
posted by kiikurin
2 comments posted 22yrs posted by kiikurin

Conversion of NCD files from 5.X to 6.1X, problem.

untyped for FragLib.ltl Writing file calntop_61.ngm... Constraining slice packing based on guide NCD. Running directed...
0 comments posted 22yrs
posted by kelvin8157
0 comments posted 22yrs posted by kelvin8157

Virtex and Spartan

Hello can anyone say me what is the difference between virtex and spartan fgpa chips. It is just the number of gates in...
3 comments posted 22yrs
posted by bhadrig
3 comments posted 22yrs posted by bhadrig

AFX BG560 board

Hello I am trying to use AFX BG560-100 board from xilinx.(http://www.xilinx.com/xlnx/xebiz/board_detail.jsp?key=HW-AFX-...
3 comments posted 22yrs
posted by bhadrig
3 comments posted 22yrs posted by bhadrig