Field-Programmable Gate Arrays

15255 Threads Posts
to

example for excalibur epxa1

Hello, does anyone have an example for a circuit using an AMBA bus on the excalibur epxa1? I built a circuit with the f...
0 comments posted 22yrs
posted by zhangdidi
0 comments posted 22yrs posted by zhangdidi

Example for Excalibur EXPA1

Does anybody have an example for Excalibur EXPA1 using an AMBA Bus? I built a circuit with a processor, a stripe_pld_ma...
2 comments posted 22yrs
posted by zhangdidi
2 comments posted 22yrs posted by zhangdidi

Suse 9.1 Linux and Xilinx ISE 6.2i

Hello, I just installed Xilinx ISE 6.2i on a Linux box and it is sluggish as anything. Does anyone know why? I am runni...
22 comments posted 22yrs
posted by sheikh
22 comments posted 22yrs posted by sheikh

MGT pin details(Xilinx Virtex 2 PRO)

Hi all, I am using Xilinx viretx 2 pro device (1152)package which has 8 MGT's. for each of the MGT there are 9 dedicate...
2 comments posted 22yrs
posted by praveenkn123
2 comments posted 22yrs posted by praveenkn123

C Header files for User Design Logic in the Nios.

Hello Guys, I am using the SOPC builder to design a simple system that integrates a couple of UARTS, a soft processor a...
8 comments posted 22yrs
posted by etd606
8 comments posted 22yrs posted by etd606

Progress in FPGA static Icc timeline degrade

In 2003, Xilinx was saying higher static power was an inevitable price of progress, and that speed was king, and nothin...
0 comments posted 22yrs
posted by no.spam
0 comments posted 22yrs posted by no.spam

Arjen Jongeling, een oude bekende

Hoewel, Arjen Jongeling is hier nog nooit geweest en ik denk dat Arjen Jongeling hier ook nooit meer zal terugkomen. St...
0 comments posted 22yrs
posted by noem
0 comments posted 22yrs posted by noem

Using Altera libraries for Nios Dev Board

Hi, I'm currently working on a project at my university for testing and developing rate based protocols and I've been h...
2 comments posted 22yrs
posted by jolivier
2 comments posted 22yrs posted by jolivier

pulse generation using SRL16E on a Virtex-II

Hi all, I'm using the code below to generate a pulse which is 16x57600 from a 51.2 MHz clock signal to controll the sam...
11 comments posted 22yrs
posted by johbe
11 comments posted 22yrs posted by johbe

Starter Kit for Linux in Virtex?

Hi I want to build an application with linux running in virtex2pro with ethernet and usb. Now I want to calculate. How...
0 comments posted 22yrs
posted by nospam
0 comments posted 22yrs posted by nospam

Library Mapping

Hi, I want to perform a timing simulation in Modelsim. For that purpose it is necessary to do a library mapping for the...
0 comments posted 22yrs
posted by ALuPin
0 comments posted 22yrs posted by ALuPin

Altera CLKLK_FB use when OPERATION_MODE=NORMAL

Hi, I am currently using an APEX20KE device. When using the altclklock megafunction, I use OPERATION_MODE = NORMAL. I w...
3 comments posted 22yrs
posted by prv3299
3 comments posted 22yrs posted by prv3299