Field-Programmable Gate Arrays

15255 Threads Posts
to

VCCO on bank 0

Hi, all, I got a "The IO standards specified for IOs in Bank0 are not VCCO compatible" error when I ran DRC in the PACE...
0 comments posted 21yrs
posted by jshen
0 comments posted 21yrs posted by jshen

EPCS16 & NIOS2 Custom board

It's possible to make NIOS board with EPCS16? (EPCS1&EPCS4 yes). I can't make custom target board design for programmin...
0 comments posted 21yrs
posted by vboykov
0 comments posted 21yrs posted by vboykov

Best solution for pci target and backend interface

I use in my project a pci target ( it a free core from Lattice). I must to control some devices (a few motors and other...
0 comments posted 21yrs
posted by dan.costin
0 comments posted 21yrs posted by dan.costin

Register names in Quartus Signal Tap Node finder

Hei, using the Quartus SignalTap Node finder i encountered the following problem. When i use a graphical designfile (*....
1 comments posted 21yrs
posted by talt
1 comments posted 21yrs posted by talt

Utilisation of Xilinx FPGAs

Dear All, I hope that you can help. I am looking at trying to fit a number of IP cores into a single Xilinx FPGA, I hav...
9 comments posted 21yrs
posted by simon.stockton
9 comments posted 21yrs posted by simon.stockton

Altera Flex10K Fast Output Register warning

Hello all I have a perfectly reasonnable design with bidir pins, written in the purest VHDL style: lberr_b
3 comments posted 21yrs
posted by matringe.nicolas
3 comments posted 21yrs posted by matringe.nicolas

Tracking down HardWired History

Hi. I'm looking for information on Xilinx's original HardWired family, which were litteral replacements for FPGAs, rath...
9 comments posted 21yrs
posted by bill
9 comments posted 21yrs posted by bill

Spartan-3 PQ/TQ/VQ SSO guidelines

Following up on this old thread: http://groups-beta.google.com/group/comp.arch.fpga/msg/b7abbb85cd4b93ba Good News of t...
6 comments posted 21yrs
posted by brimdavis
6 comments posted 21yrs posted by brimdavis

iMPACT 5.1i w/Parallel Cable

Hello everyone. I have been having some trouble with iMPACT 5.1i and I was hoping that someone would recognize the prob...
4 comments posted 21yrs
posted by milne
4 comments posted 21yrs posted by milne

SysGen installation problem

Hi, When I try to install SysGen6.2, the following error message appeared. >> setup Welcome to the Xilinx System Genera...
0 comments posted 21yrs
posted by stmak
0 comments posted 21yrs posted by stmak

Re: Latches

Joel, The second process is a combinatorial process. All signals must be assigned a value for all conditions, or a latc...
1 comments posted 21yrs
posted by newman5382
1 comments posted 21yrs posted by newman5382

Help needed getting started with virtex II pro

hi I need to start working on a xilinx virtex II pro board in a few days. I am new to fpgas. Could someone please sugges...
1 comments posted 21yrs
posted by jain.akshay
1 comments posted 21yrs posted by jain.akshay

Extracting BRAM data from configuration Bit stream

Hello, I am developing a partial reconfigurable system and one of the requirements of my system is that one needs to re...
0 comments posted 21yrs
posted by harish.vutukuru
0 comments posted 21yrs posted by harish.vutukuru

Extracting BRAM data from bitsream

Hello, I am developing a partial reconfigurable system and one of the requirements of my system is that one needs to re...
1 comments posted 21yrs
posted by harish.vutukuru
1 comments posted 21yrs posted by harish.vutukuru

Location of Data in BRAM Configuration bit stream

Hello, If I configure Xilinx BRAM for a data width greater than 1, say 8 then will all the 8 bits corresponding to the...
0 comments posted 21yrs
posted by harish.vutukuru