Field-Programmable Gate Arrays

15255 Threads Posts
to

Debug module and bufg in Xilinx EDK

Hi all, My problem is as follows: when I'm inserting a mdm (debug module) to my microblaze project it automatically add...
0 comments posted 21yrs
posted by moti
0 comments posted 21yrs posted by moti

error in xst

Hi I'm making a design and my top uses 2 differents models of memory (ROM) that I declare in vhdl using an array struct...
1 comments posted 21yrs
posted by kclo4
1 comments posted 21yrs posted by kclo4

Altera's NIOS2 examples...

Looking at the NIOS2 1.1 design examples I wonder why in the "standard" design the SDRAM pll is of type "Stratix" thoug...
3 comments posted 21yrs
posted by me
3 comments posted 21yrs posted by me

OPB ZBT

Hi! I was wondering why my EDK 6.3 doesn't include this controller although it is listed here: http://www.xilinx.com/ise...
1 comments posted 21yrs
posted by alles
1 comments posted 21yrs posted by alles

Coprocessor "Standalone"

Hi I have the following question: I have built a "coprocessor" which performs some special arithmetic operation. Until...
0 comments posted 21yrs
posted by ernte23
0 comments posted 21yrs posted by ernte23

EDK+IPIF: Customizing wizard result

Hi, I have created a periperal IP device using the "Create/Import.." wizard of the EDK 6.3. The IP has 4 32 bit registe...
4 comments posted 21yrs
posted by nussehund
4 comments posted 21yrs posted by nussehund

vieux livres

bonjour, je fais du tri dans ma bibliothèque et je ne peut me résoudre à poubeller certains vieux bouquins de ma jeunes...
1 comments posted 21yrs
posted by ANTISPAMMMusmgn
1 comments posted 21yrs posted by ANTISPAMMMusmgn

ambiguous number of BLOCK RAM in SPARTAN3

When i synthesize my design in a SPARTAN3 XCS400 FPGA the synthesis report says that there are 8 blockRAMs available in...
1 comments posted 21yrs
posted by vasus_ss
1 comments posted 21yrs posted by vasus_ss

Re: RoseRT + Threadx + Xilinx Microblaze

>Has someone good or bad experience with >the RoseRT + ThreadX + Microblaze flow? I could be wrong, but I'd guess the c...
0 comments posted 21yrs
posted by usenet
0 comments posted 21yrs posted by usenet

This Is My Task - Have A Look

Hey I am working for the editorial board of a PC magazine. I heard news that there is this free online game that has on...
0 comments posted 21yrs
posted by teapot027
0 comments posted 21yrs posted by teapot027

memory size of C code

hi after compilation of microblaze C code the log file says ---------------------------------------------- mb-size MB0/...
1 comments posted 21yrs
posted by JEmoderatz
1 comments posted 21yrs posted by JEmoderatz

Multi-Master problem with OPB

Hi! I have a big problem with connecting multiple masters to the OPB. I connected the Microblaze-Processor and a VGA-Co...
0 comments posted 21yrs
posted by alles
0 comments posted 21yrs posted by alles