The 6.1i/6.1i SP1 unisim DCM model doesn't work in a simulation that works with the model included in 5.2i SP3. Has anyone else experience the same problem? What has been changed? Why is the model changed?
/Patrik Eriksson
The 6.1i/6.1i SP1 unisim DCM model doesn't work in a simulation that works with the model included in 5.2i SP3. Has anyone else experience the same problem? What has been changed? Why is the model changed?
/Patrik Eriksson
"Patrik Eriksson" a écrit dans le message de news: snipped-for-privacy@netinsight.net...
Unisim DCM model is change and now the RST signal must be asserted for 3 CLKIN clock cycles. A test exists in VITAL model to print a message if the timing is not correct but the test doesn't work at "power up" because a signal is not correctly initialized.
To make this working, do the folowing modifications.
in "unisim_VITAL.vhd" and "simprim_VITAL_mti.vhd" files replace all occurences of the folowing line signal rst_reg : std_logic_vector(2 downto 0); by : signal rst_reg : std_logic_vector(2 downto 0) := "000"; and compile the modified files.
Now the simulation must generate an error like: # ** Error: Timing Violation Error : RST on instance * must be asserted for
3 CLKIN clock cycles. # Time: 30 ns Iteration: 3 Instance: /testbench/u_2/dcm_iGerard Thierry