Charge pump vs. phase detector gain for a PLL

Aug 17, 2006 2 Replies

When calculating PLL loop filter values, one need to know the phase detector gain in mA/Hz for a "charge pump phase detector". Very often the charge pump current is defined if you are using a synthesiser chip. My question is therefore: What is the relationship between phase detector gain in mA/Hz and charge pump current in mA? I often see in literature that they define the ratio between phase detector gain and charge pump current as a 1:1 ratio. But is this really correct?



That is not correct... it is mA/radian

Nope. Read the data sheet more carefully.

...Jim Thompson

| James E.Thompson, P.E. | mens | | Analog Innovations, Inc. | et | | Analog/Mixed-Signal ASIC\'s and Discrete Systems | manus | | Phoenix, Arizona Voice:(480)460-2350 | | | E-mail Address at Website Fax:(480)460-2142 | Brass Rat | | http://www.analog-innovations.com | 1962 | I love to cook with wine. Sometimes I even put it in the food.

Yes. the gain is current / phase delta

very often the data sheet will give you the full scale current output where full scale is +2pi radians (+360 degrees) and -2pi radians (-360 degrees).

Mark