Toshiba TV model 27A44, Regulated B+ Info

Dec 03, 2008 2 Replies

Hi,



I have a Toshiba TV (27" pic) model 27A44 (mfg. 05/04) in my TV service shop (no SM). Customer told me the TV "sparks" once in awhile, then turns off. It didn't do it in the shop yet, but checking the HV, it was 30KV (higher than normal). I checked the regulated B+ and it measured +122V! Unfortunately, there is no marking on PCB that indicates what this voltage should be.



I removed and tested the timing capacitors in the horizontal output circuit. Sometimes an open capacitor will cause the HV to go higher than normal. They tested just fine.



130V is very common in my experience, but can someone tell me what the regulated B+ should be in this model TV?

Thanks in advance, Brad



Before you type your password, credit card number, etc., be sure there is no active keystroke logger (spyware) in your PC.



On Wed, 03 Dec 2008 14:56:54 GMT, snipped-for-privacy@verizon.net (Brad) put finger to keyboard and composed:

I can't help with your particular model, but I recently had to determine the B+ voltage for a supermarket branded 34cm TV. The B+ capacitor was rated at 250V but the B+ was measuring only 103V. It turned out that this was correct.

What I did was to trace out the circuit around the optocoupler between the primary and secondary sides of the switching transformer. The voltage sensing IC was a TL431.

2.5V | B+ o-- R2 --o-- TL431 --> to optocoupler | R1 _|_ =

In the circuit above, the value of B+ can be computed from ...

B+ = (1 + R2/R1) x 2.5

- Franc Zabkar

Please remove one \'i\' from my address when replying by email.

On Wed, 03 Dec 2008 14:56:54 GMT, snipped-for-privacy@verizon.net (Brad) put finger to keyboard and composed:

This forum post talks about a B+ of 124V and an EHT of 25kV:

formatting link

- Franc Zabkar

Please remove one \'i\' from my address when replying by email.

Join the Discussion

Have something to add? Share your thoughts — no account required.

Didn't find your answer?

Ask the community — no account required