flyback

Hi! I need to know the draw # for a flyback transformer for an RCA Chassis CTC203AAA9. Thank yoy Vince

Reply to
Vince Schmitt
Loading thread data ...

=A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 Thank yoy

=A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0Vince

What do you mean "the draw"

Do you mean a schematic showing the windings and terminal numbers, or the current levels going through the transformer when the TV is operating????

Reply to
hrhofmann

=A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 Thank yoy

=A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0Vince

Database shows part number 244229 for your chassis version, but TCE TVs have had issues with the numbers on the original fly needing to be researched. Do you have the original and are the numbers legible?

John

Reply to
John-Del

On Sun, 19 Jun 2011 16:16:37 -0700 (PDT), John-Del put finger to keyboard and composed:

FYI, here is a HR Diemen substitute:

formatting link

Unfortunately its information URL gives me an "internal server error":

formatting link

It usually has a winding diagram with voltage information.

- Franc Zabkar

--
Please remove one 'i' from my address when replying by email.
Reply to
Franc Zabkar

is

=A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 Thank yoy

=A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0Vince

An older RCA part program (back when RCA was actually a viable company) shows a DRAWING number (the number actually on the fly) of XX15361-19A That number is only useful if you're scrounging for a used one as RCA didn't put the actual part number on the parts because they were subject to upgrades with new part numbers. The old program also agrees that 244229 is the correct PART number, and it's NLA. Various subs work, but sometimes have issues with geometry or ABL or pix tearing problems. I've never used an H.R. in this chassis, but if their sub is typical of other H.R.s I've used, I wouldn't be afraid of it.

John

Reply to
John-Del

ElectronDepot website is not affiliated with any of the manufacturers or service providers discussed here. All logos and trade names are the property of their respective owners.