Field-Programmable Gate Arrays

15255 Threads Posts
to

An old FPGA paper back to 1986...

W. S. Carter et al., "A user programmable reconfigurable logic array," in Proc. Custom Integr. Circuits Conf., 1986, pp....
1 comments posted 22yrs
posted by sunroof_2002
1 comments posted 22yrs posted by sunroof_2002

Why warnings: "Input <xyz> never used???"

Hi: I am building my first Verilog project with Xilinx WebPack 5.2i. I have a module test_delay8 that instantiates a mo...
6 comments posted 22yrs
posted by crcarle
6 comments posted 22yrs posted by crcarle

Warning on DCM min frequency...

Hi, there: I am using a Virtex-2's DCM to convert a 40MHz clock into synchronized 12MHz (40X3/10) and 4MHz (40/10) cloc...
1 comments posted 22yrs
posted by kelvin8157
1 comments posted 22yrs posted by kelvin8157

Stratix 2 ALUT architecture patented ?

Hi, is the new ALUT architecture of stratix 2 patented ? I have looked at the US patent office but could not find such a...
34 comments posted 22yrs
posted by lenz19
34 comments posted 22yrs posted by lenz19

Experience with Simulating RocketIO in Modelsim

Does anyone have any experience simulating RocketIO in Modelsim SE via use of SmartModels. I am trying to stimulate the...
1 comments posted 22yrs
posted by tcampbel
1 comments posted 22yrs posted by tcampbel

Verilog Newbie Question

The following code is my first Verilog program. It's running at 25MHz and that's what the counter is for. I'm trying to...
5 comments posted 22yrs
posted by lsdjf
5 comments posted 22yrs posted by lsdjf

spying on signals in Quartus (newbie question)

Hi, When debugging a design one can assign inside the VHDL code debug pins. However, if after compiling and everything...
1 comments posted 22yrs
posted by vrusu
1 comments posted 22yrs posted by vrusu

DCM Simulation Error

I am using Modelsim SE 5.8 to simulate cascaded DCMs. I have two DCMs cascaded, the first with CLKIN running at 10Mhz....
3 comments posted 22yrs
posted by tcampbel
3 comments posted 22yrs posted by tcampbel

Spartan 2 XC2S400E and XC2S600E availabillity

Can recommend a decent supplier of the above parts in small qty for the UK? I've tried Emailing Insight Memec who have...
2 comments posted 22yrs
posted by tau14
2 comments posted 22yrs posted by tau14

JTAG Opcodes for Altera MAX7000S

Hi, I try to program a JTAG chain with a MAX7064S and a MAX7032S via JTAG with a microcontroller. The problem is, that...
3 comments posted 22yrs
posted by pclad.adr
3 comments posted 22yrs posted by pclad.adr

SRAM bidirectional bus

Hi, I have a question concerning the VHDL description of a bidirectional bus. This bus comes from (goes to) an SRAM whi...
3 comments posted 22yrs
posted by ALuPin
3 comments posted 22yrs posted by ALuPin

ngd2edif vs. ngc2edif

I have some questions regarding Xilinx design flow. What NGD and NGC files are? Is edif file created by the 2edif tools...
3 comments posted 22yrs
posted by valentin_NOSPAM_NOWORMS
3 comments posted 22yrs posted by valentin_NOSPAM_NOWORMS

Spartan 3 / XCF02S JTAG problem

I have a board that has a XCF02S and Spartan 3 400 (ES) connected in a JTAG chain (the XCF02S is first in the chain). A...
2 comments posted 22yrs
posted by jon
2 comments posted 22yrs posted by jon

Routing algorithm - help needed

Consider the grid shown below. There are 4 electrical "switch pairs" which need to be connected to make the overall con...
2 comments posted 22yrs
posted by chjones
2 comments posted 22yrs posted by chjones