Field-Programmable Gate Arrays

15255 Threads Posts
to

Can PPC in V2P reconfig the FPGA slices?

If I have a PPC BRAM program running on a V-II Pro, can it reconfig the CLB slices? I'd like to be able to do this w/o...
13 comments posted 22yrs
posted by jim
13 comments posted 22yrs posted by jim

FPGA programming issue with Xilinx POD and PROM

Hi everyone I am having a strange problem with programming Xilinx XC2s200 FG 256. Following is a brief description: 1)...
0 comments posted 22yrs
posted by krishk24
0 comments posted 22yrs posted by krishk24

xilinx Synthesis report - please help..

Hi all, I'm cuurently working on a xilinx spartan 2e design, for debug I'm using the chipscope pro LA. the problem is a...
3 comments posted 22yrs
posted by moti
3 comments posted 22yrs posted by moti

95108 doesnt program

I have a few XC95108 (-20 speed grade), PC84 package. One of them programs OK using a self designed test board and xili...
0 comments posted 22yrs
posted by dvgadre
0 comments posted 22yrs posted by dvgadre

IEDCS'04 Design Contest

IEDCS'04 -1st International Electronics Design Contest for Students www.handasa-arabia.org/iedcs04 Handasa Arabia (www....
0 comments posted 22yrs
posted by mosalem2003
0 comments posted 22yrs posted by mosalem2003

Different capabilities

Hello. Im a new masters degree student and i want to have a kit at home. I need help on selecting the right development...
2 comments posted 22yrs
posted by nospam
2 comments posted 22yrs posted by nospam

How to ? 2.1i to ISE6.2 SCHEMATIC converter!!

Anybody knows how convert schemtic from Xilinx 2.1 to ISE6.2 Webpack? It is very strange that ISE6.2 cannot convert earl...
4 comments posted 22yrs
posted by cubah
4 comments posted 22yrs posted by cubah

CLOCK_SIGNAL Constraint.

Hi everybody... I m deriving 4 clocks in my module, are all gated with respect to a synchronous individual clock enable...
1 comments posted 22yrs
posted by chandu_419
1 comments posted 22yrs posted by chandu_419

How big is LEON on Virtex2?

I want to implement Leon on xc2v1000. But only one Leon core (only IU, Icache and Dcache) occupies 99% SLICE. Can I put...
0 comments posted 22yrs
posted by zhao0043
0 comments posted 22yrs posted by zhao0043

get net name after place and route, ISE

Hi all, I am using ISE 6.2 and after place and route static timing analysis I see a net in my critical path that looks...
0 comments posted 22yrs
posted by mer2
0 comments posted 22yrs posted by mer2

new XILINX 9500XL datasheets

hello ng, there are new versions of the 9500xl cpld devices on the xilinx server. See:...
3 comments posted 22yrs
posted by techseller
3 comments posted 22yrs posted by techseller

DDR Lines on FPGA : Physical considerations

Hi, Follow up to a preceding post, I finally decided to use DDR : 2 chips of 16bits wide to have 32bits bus. Since I go...
4 comments posted 22yrs
posted by tnt_at_246tNt_dot_com
4 comments posted 22yrs posted by tnt_at_246tNt_dot_com