Field-Programmable Gate Arrays

15255 Threads Posts
to

EDK OPB Uart 16550

We are using the trial version of the OPB Uart 16550 in one of our designs. We are running this at 19200,8,N,1, no flow...
2 comments posted 22yrs
posted by wpiman
2 comments posted 22yrs posted by wpiman

Xilinx RocketPHY Development Kit (HWK-RPHY-DVLP)

Hello everyone: I am design engineer and in the process of evaluating the Xilinx RocketPHY Development Kit (HWK-RPHY-DV...
0 comments posted 22yrs
posted by onenanometer
0 comments posted 22yrs posted by onenanometer

Help with Coregen ROM in ISE 6.2.03i

I'm very new to working with Xilinx tools so I may be overlooking something obvious. I'm able to synthesize with XST an...
0 comments posted 22yrs
posted by jmkerwin
0 comments posted 22yrs posted by jmkerwin

Xilinx S3 Serial Port Code

Hello Every1, I am looking for VHDL code for a serial port. Small. Fixed Baud rate. Perhaps only output, don't know tha...
2 comments posted 22yrs
posted by bradsmallridge
2 comments posted 22yrs posted by bradsmallridge

ERSA low cost BGA assembly system?

Hi, I'm thinking about ERSA IR 500/550 A, Universal BGA/MST Rework systems. Does anybody have an idea about the price o...
0 comments posted 22yrs
posted by arash.salarian
0 comments posted 22yrs posted by arash.salarian

Spartan 2E gets hot after configuration

Hi all, I have a board that has an XC2S300E-6PQ208 on it that gets hot after I configure it. Before the FPGA is configu...
2 comments posted 22yrs
posted by info
2 comments posted 22yrs posted by info

EDK

hi, Can any one tell me how, i can compile my application in EDK for montavista linux... Regards, Mack.
1 comments posted 22yrs
posted by mmkumar
1 comments posted 22yrs posted by mmkumar

Adding a Delay2

I need to delay one of the output signals from my cpld by 80nS. The clock frequency of our board is 48MHz. Im using the...
3 comments posted 22yrs
posted by agarvey
3 comments posted 22yrs posted by agarvey

clock divider

Hello I'm looking for information about clock dividers. I need information about clock dividers that can divide an 100M...
3 comments posted 22yrs
posted by rune.christensen
3 comments posted 22yrs posted by rune.christensen

Unwanted shift in multiplier

Hello: I am building a add-shift multiplier in Quartus and i seem to end up having a product that is multiplied by two...
1 comments posted 22yrs
posted by prasunp
1 comments posted 22yrs posted by prasunp

AHB-Slave

Hi, When the current AHB slave is busy (hready low) servicing the Master,but if the master drives IDLE transfer in the...
1 comments posted 22yrs
posted by mmkumar
1 comments posted 22yrs posted by mmkumar

Can ACEX work well in high EMI environment?

I want use ACEX to take place of MAX7000 in motion control systems. As ACEX is based on SRAM technology, I wonder if It...
0 comments posted 22yrs
posted by panwenhui_shiji
0 comments posted 22yrs posted by panwenhui_shiji