Field-Programmable Gate Arrays

15255 Threads Posts
to

Programming Virtex II in slave select MAP mode?

Hi everybody, I want to program a embedded microcontoller to load a configuration bitstream using the slave select MAP...
2 comments posted 21yrs
posted by kiran
2 comments posted 21yrs posted by kiran

Clock Synchronization

I am looking for some material about the various clock synchronization techniques, their advantages etc. Thanks Neil
6 comments posted 21yrs
posted by logblog
6 comments posted 21yrs posted by logblog

FIFO WREN RDEN and missing clock cycle

Hi folks, I have run into this problem before, and I just can't put a handle on it. I use the code before to generate r...
2 comments posted 21yrs
posted by bradsmallridge
2 comments posted 21yrs posted by bradsmallridge

PCI doubt

hi there, i have a (probably very fundamental) doubt regarding PCI - what is the difference between a PCI master, arbite...
6 comments posted 21yrs
posted by shyran
6 comments posted 21yrs posted by shyran

New HDLmaker release

I've uploaded a new release of HDLmaker, revision 7.3.3. HDLmaker is an open source Verilog hierarchy builder for build...
0 comments posted 21yrs
posted by bjrosen
0 comments posted 21yrs posted by bjrosen

Problem with SOPC Builder in Quartus 4.0

Hi all, I am using Altera Quartus 4.0 edition, which is working fine, as far as compilation of designs etc. is concerne...
3 comments posted 21yrs
posted by vizziee
3 comments posted 21yrs posted by vizziee

Digital clock synthesis

This is leftover from a couple of discussions a week or two ago. There is something interesting that I don't understand...
23 comments posted 21yrs
posted by hmurray
23 comments posted 21yrs posted by hmurray

Xilinx ISE 6.3.03i service pack size

Just got the popup about the ISE 6.3.03i service pack, went to the Xilinx site and the page says 6_3_03i_pc.exe is 110Mb...
3 comments posted 21yrs
posted by geeja.ats
3 comments posted 21yrs posted by geeja.ats

PACE question

I've been using PACE, which is a pretty nice tool. It has less functionality but is much easier to use than Floorplanne...
0 comments posted 21yrs
posted by kevin_neilson
0 comments posted 21yrs posted by kevin_neilson

storing convolution coeeff's Xilinx V2 8000

I would like to store several hundred convolution coefficients for a real time computer vision core using Xilinx's V2 8...
1 comments posted 21yrs
posted by wallge
1 comments posted 21yrs posted by wallge

Xilinx FIFO

I am using coregen to generate FIFOs for my design and get typically 77LUTs and 38Registers for a 1 BLOCK RAM FIFO. See...
6 comments posted 21yrs
posted by bradsmallridge
6 comments posted 21yrs posted by bradsmallridge

Inferring SRLs with INIT value

Synplify now reads the defparam 'INIT' used for instantiated SRLs, so you can initialize the value of the SRL16 for bot...
5 comments posted 21yrs
posted by kevin_neilson
5 comments posted 21yrs posted by kevin_neilson

JTAG vs. Passive Serial Config speed

Hi Is there a significant difference in the time it takes to download a configuration to an Altera Cyclone (EP1C6) usin...
1 comments posted 21yrs
posted by kawk
1 comments posted 21yrs posted by kawk

Quartus II Graphic Editor Anomaly?

I have a bdf schematic with some pins labeled DAI[13..1] & and DAI[14], DAI [15], etc. I have different pins labeled in...
4 comments posted 21yrs
posted by dsp
4 comments posted 21yrs posted by dsp