Field-Programmable Gate Arrays

15255 Threads Posts
to

Altera Stratix synthesis error

I have transported a design from Altera APEX to STRATIX. The previous design´s Lookup Tables (LUTs) that were in ¨lpm_r...
2 comments posted 22yrs
posted by janos.nojunk.nospam.ero
2 comments posted 22yrs posted by janos.nojunk.nospam.ero

CFP: EH-2004 Second Call for Abstracts

Dear Colleague, The abstract submission deadline (December 1st, 2003) for the 2004 NASA/DoD Conference on Evolvable Har...
0 comments posted 22yrs
posted by eh-2004
0 comments posted 22yrs posted by eh-2004

CPLD : Generating reset signal

Active reset is high. In passive state (nRESET) I pull signal to GND with 130k resistor. Pushing a button connects sign...
6 comments posted 22yrs
posted by valentin
6 comments posted 22yrs posted by valentin

Problems Configurating MicroBlaze into RC200 board

I have been following several tutorials to build a simple system that only prints a string by the serial port. My syste...
2 comments posted 22yrs
posted by m_perez_gutierre
2 comments posted 22yrs posted by m_perez_gutierre

PCI interface with attached PLD

I need to build a PCI interface - could be 64 bytes of write-only latches and 1 byte of status readback. Then I want to...
9 comments posted 22yrs
posted by from_usenet_comp_arch_fpga
9 comments posted 22yrs posted by from_usenet_comp_arch_fpga

SPI 4.2 Core perceptions and Power

Has Anyone used the SPI 4.2 Core? How well is it implemented? Any idea of the power consumption? I'm wondering if the 2W...
0 comments posted 22yrs
posted by dan-schaffer
0 comments posted 22yrs posted by dan-schaffer

%age occupation of interconnect resources

I was wondering how much (in percentage terms, roughly) the interconnect resources occupy in a typical FPGA. Is there an...
0 comments posted 22yrs
posted by nc300
0 comments posted 22yrs posted by nc300

None

Thanks. I read this manual but I didn't find how to visit CF card to get = the data there. I don't mean to generate a s...
1 comments posted 22yrs
posted by yuwei
1 comments posted 22yrs posted by yuwei

microblaze as submodule

Hi, I'm using a design which contains a microblaze system as submodule. In the microblaze design there are interrupt us...
3 comments posted 22yrs
posted by someone
3 comments posted 22yrs posted by someone

using multilinx from ISE to download a bit file

I have ISE 5.2 on winXP and I have a multilinx download cable. I am trying to download a bit file via the multilinx cab...
1 comments posted 22yrs
posted by pixelsmart
1 comments posted 22yrs posted by pixelsmart

xilinx platform flash question

I need to configure an XC2V6000 from flash. Planning to use six XCF04S PROMs, but I have a few questions. 1. Anyone hav...
1 comments posted 22yrs
posted by rsefton
1 comments posted 22yrs posted by rsefton

Memory Initialization: mif, coe, hex, etc,

Hi experts, I've looked through the archives, and the Xilinx literature, and haven't found an answer to this question,...
8 comments posted 22yrs
posted by yeah_spam_me
8 comments posted 22yrs posted by yeah_spam_me