Hi All,



I discovered that I use in my working application the x2 Clock Output as the feedback - after the GBUF - for a DLL that deskews a 48Mhz input clocks and provides to output clocks for internal usage.



Is this wrong, I am not shure anymore, however I read in XAPP132 and XAPP174 that you have to use x1 output signal - after the GBUF - if you want to to make use of an internal x1 and x2 clock that are in phase, controlled by one DLL...



A short note would help



markus



Mit freundlichen Grüssen Markus Meng P.S. Achtung wir haben eine neue FAX-Nummer ******************************************************************** ** Meng Engineering Telefon 056 222 44 10 ** ** Markus Meng Natel 079 230 93 86 ** ** Bruggerstr. 21 Telefax 056 222 44 34

The DLL can handle either a 1x or 2x clk as it's feedback. It just can't use the fx or phase offset ouputs as the feedback

Markus Meng wrote: > Hi All, >