Thurlby Logic Analyser LA4800 RS423

Hello,

Has anyone had any experience of hooking up an LA4800/3200 to a PC running it's LATALK Dos software?

The RS423 interface is described as RS232 compatiable but if you plug in a straight RS232 cable from PC to LA then the PC doesn't see the LA.

I've looked into this further and RS423 is almost a completely different standard and levels to RS232. So a bit confused as to how the interface is described as RS232 compatiable.

Thurlby have been brilliant in that they supplied the LATALK software a few weeks back but with the LA4800 being discontinued and unsupported the information I need isn't readily at hand.

Any ideas?

Thanks kindly,

Alison

Reply to
Aly
Loading thread data ...

423 and 232 are to all intents the same for the majority of applications - 232 just swings further.

bear in mind that this instrument dates back to when computers other than PCs were not uncommon , and so the D9 pinout may not be expecting to be plugged directly into a PC without some pin-juggling. You may also need to do things like loop back handshake pins.

Start by confirming the TX/RX direction - at the connector, 0V will be in input (receive) and more than a volt negative will be an output (transmit)

Reply to
Mike Harrison

Hi Mike,

This is what I have so far from the manual.. " The analyser is fitted with a bi-directional RS-423 serial interface which is fully compatiable with equipment fitted with an RS-232 interface. The interface can be operated at either 1200 or 9600 baud (selectable from the configuration screen).

The connections for the interface are as follows:

5 4 3 2 1 9 8 7 6

1 = +5V

2 = DATA IN 3 = DATA OUT 4 = 5 = GND 6 = 7 = RTS (O/P) 8 = CTS (I/P) 9 = -5V

Note that the interface in not isolated and that signal ground for the interface is directly connected to chassis ground.

The interface is used for the printer output, and can be used for bi-directional transfer of data and for full remote control of the analyser. The commands for data transfer are listed in Appendix B. "

So that's about it. I've tried patching what seems like all sorts of combinations TX to RX, TX to TX,. CTS to CTS, CTS to RTS. I've even tried doing thing on an older generation genuine IBM PC-AT which usually when comms issues arise solves most problems.

From what I've read so far on the net RS232 and RS423 are two almost completely different standards, so am wondering if anyone has done this, been in this position etc?

Kind thanks,

Aly

Reply to
Aly

As PCs put data out on pin 23, you will need to crossover pins 2/3. I'd suggest looping back the handshake lines at each end, i.e. link pins 7/8 at each end, and maybe also DTR to DSR at the PC end.

No they are not. The only difference is the voltage swing, and this can be ignored in pretty much all cases as RS423 levels will work a 232 receiver and a 423 receiver will tolerate RS232 12V swings. .

Reply to
Mike Harrison

DONE!!

2 - 3 3 - 2 4 * 5 - 5 6 * 7 - 8 8 - 7

(-) = link to (*) = short with

Many many thanks Mike!! Cheered me up that has :-)

Huge thanks,

Alison, Cambridge UK

Reply to
Aly

With Mike's help.. to reiterate. The correct wiring between a standard PC

9-pin serial port and a Thurlby LA3200/4800 is:

2 - 3

3 - 2 4 * 5 - 5 6 * 7 - 8 8 - 7

(-) = link to (*) = short with on PC side

Reply to
Aly