Sed1335 with LPC2294

Jan 03, 2006 2 Replies

Hello to you all.



Has anybody used successfully the SED1335 device in bus mode with LPC



2294 (the ARM7 from Philips)?

I'm using a Phytec development board, which uses the A2 address bus as the lowest bit for the addresses. The register BCFG3 seem to correctly set:



BCFG3 --> 0x0000FBEF



bit memory access, RBLE = 0, IDCY=15, WST1=31, WST2=31.



I have also set PINSEL2 to 0x0E6149E4, using the bus in A2-A23, enabling CS3 (at address 0x83000000).



The symptom is that when I write to 0x83000000 A2 does not go to 1.



Any idea?



thank you in advance -- bugfixer



Oh, a typo:

"The symptom is that when I write to 0x83000001 A2 does not go to 1. "

is the correct information.

oops, sorry. Now A2 moves. I have to write to 0x83000004 to make it move. Sorry. I hope this at least helps somebody else.

-- bugfixer