Can I run this pump on 60 hz with/without a converter. If I need a converter,...
J
John Popelish
formatting link
It will run 6/5 of normal speed, and the capacitor may not be quite optimal, but it will almost certainly work for a while.
The big problem with motors is normally running 60 Hz motors on 50 Hz, because they draw more current at lower frequency.
The pitfall running a 50 Hz motor on 60 Hz usually involves them being loaded with centrifugal pumps, that require more torque at higher speed, while the motor torque drops when you raise the frequency, without raising the voltage.
But this pump should not require a higher torque in proportion to the higher speed.
R
Ralph Mowery
formatting link
It is probably way over kill but you could use something like this:
formatting link
I have no idea how much they cost but have installed about 30 or so where I work and they give almost no problems.
P
Phil Allison
"Preston Andreas"
** You do have 240 volts at 60 Hz ??
........ Phil
J
Jamie
formatting link
i do think that will work how ever, you may find it producing more RPM's on no load and drop faster when its loaded due to less torque involved.