I have a Rigol DS1102E, a 2 channel 100mc scope, that is currently showing 2 copies of the expected display, one above the other. Whether this is a bug or a feature is questionable but reseting the scope to a common state would be helpful. Anyone know if this is possible and how it's done?
Hul
Didn't find your answer? Ask the community — no account required.
D
Dave Platt
You have probably put the scope into "Delayed Scan" mode, where the lower half of the window shows a magnified view of a portion of the full sweep. You might have gotten into this mode via the horizontal menu (press horizontal MENU, then select Delayed and then On) or by pressing the horizontal scale button. The latter is probably quite easy to do by accident.
You can turn this mode back off via the menu, and (I assume) by pressing the horizontal scale button a second time.
There's also a split-screen mode if the FFT feature is enabled, but that doesn't sound like what you're seeing.
I don't see a complete "system reset" feature anywhere in the manual; I might be missing it. If it's there it's probably buried in the "Utility" menus somewhere.
H
Hul Tytus
Thanks Dave. I'll go through horizontal menu & see what happens.
Hul
Dave Platt snipped-for-privacy@co> >I have a Rigol DS1102E, a 2 channel 100mc scope, that is currently
H
Hul Tytus
Thanks John, that sounds like what's needed. Where's it located?
Hul
John Lark> > >> >>I have a Rigol DS1102E, a 2 channel 100mc scope, that is currently