Jan 11, 2007 3 Replies

Hi! I ran a simulation to see the effect of VDS versus ID of a transistor. After simulation, PSPICE plotted Id and V(M2:d) on the same graph. How do I have Id on the y-axis and V(M2:d) on the x-axis?



Thanks.


  • Schematics Netlist *



R_R1 $N_0002 $N_0001 210k V_V1 $N_0002 0 3v V_V2 $N_0003 0 10 R_R2 $N_0003 $N_0004 100k M_M2 $N_0004 $N_0001 0 0 MbreakN-X



  • L=0.001
  • W=0.001


** Analysis setup ** .DC LIN V_V2 0 10 0.1 .OP .LIB "C:\\Pspice_sch\\ex4.1a.lib"


  • From [PSPICE NETLIST] section of pspiceev.ini: .lib "nom.lib"

.INC "ex4.1a.net" .INC "ex4.1a.als"


.probe



The x-axis should already be V2 since that's what you swept.

Delete V(M2:d) from the plot.

Double click text along the x-axis, choose "axis variable", change to V(M2:d)

...Jim Thompson

| James E.Thompson, P.E. | mens | | Analog Innovations, Inc. | et | | Analog/Mixed-Signal ASIC\'s and Discrete Systems | manus | | Phoenix, Arizona Voice:(480)460-2350 | | | E-mail Address at Website Fax:(480)460-2142 | Brass Rat | | http://www.analog-innovations.com | 1962 | I love to cook with wine. Sometimes I even put it in the food.

You are welcome!

...Jim Thompson

-- | James E.Thompson, P.E. | mens | | Analog Innovations, Inc. | et | | Analog/Mixed-Signal ASIC's and Discrete Systems | manus | | Phoenix, Arizona Voice:(480)460-2350 | | | E-mail Address at Website Fax:(480)460-2142 | Brass Rat | |