Hello,
I cam across the following posting while trouble shooting the same problem with the same monitor:
The raster comes on for about 2 seconds and then goes black. I don't have the equipment to ESR the caps, so I checked for anything obvious and then checked the two two high voltage outputs CW401, 402. They are identified on the board as 800Vac 15mA max. I measured these with an AC meter and came up with one side at about 230v and the other was almost 10x that, at 2.2kv.
The funny thing is that when my test leads are across the higher output, the raster comes on and stays on as long as my meter is connected. As soon as I remove a test lead, the raster shuts off.
Testing the side with 230v doesn't make a difference. The raster stays on just long enough for my meter to capture the voltage.
I assume my power board (6871TPT285A) is no good, and will order a replacement (superseded to 6871TPT286A), but I'm wondering if it makes sense to anyone that the raster stays on when my meter is connected to the output that is reading high?
Thanks for your input! Best, Matt