Two units same situation. KV-27EXR25, KV-27EXR15, dead, IC 651 STRS6301 shorted, checked D623 Q604, & surrounding circuitry, & 2sd1886 horizontal output shorted, repaired, solder horizontal section, checked drive cap, but comes on with high voltage just for a split second, & shuts down with about 125 volts DC out of the power supply at about 75 volts AC in with B+ at the flyback unhooked. I can't see anything gone in the power supply. Am I missing something here? Thanks, Dani.
- posted