NTC MODEL: km-411 pincushon solved

hi there again!

Could anyone help me out this monitor?

NTC, model No: KM-411 The problem is low width and pincushion. It also has slight breathing. I checked diodes, and transistors in the horizontal and pinamp area but

not found the culprit. Check coils by substitution but still no effect.

Comparing the voltage from a known good monitor, I discovered that this

one has low B+ output. Measured from flyback primary winding, the good monitor has 200 volts. But the defective one has only 170 volts. Anyway, I have tested capacitors with my ESR meter in the psu and horizotal. They seem okay. Disconnecting flyback primary winding creeps

up the voltage to 215 volts. Does it mean the problem lies on the horizontal section and not on the low voltage power supply section? Where should I look now. It seems I'm lost.

Thanks in advance for troubleshooting tips. ian

Ps. Ive reposted it so that other who may ran same problem be helped a lot.

I've already found the problem. It's the flyback (LOPT). Substituted it by a known good one and the set was fixed. I just dont know why flyback fails this way. I guess its defective internally. Maybe partially shorted or open. I am not sure. Its because

when i disconnect the B+ supply in the primary winding of the flyback before the problem was solved, the voltages in the horizontal section creeps up to 200 volts.

So if someone encounters this problem, NTC, Model No: KM-411, if after checking yokes, capacitors esr and capacitance and other components especially in the low voltage psu and horiz section reveals nothing, a big chance its the flyback breaking down when under load.

Reply to
yhan
Loading thread data ...

ElectronDepot website is not affiliated with any of the manufacturers or service providers discussed here. All logos and trade names are the property of their respective owners.