Hitachi 50" rear projection. Dead!!

Jul 24, 2007 1 Replies

Model # 50UX57B, Chassis # AP83R, dead, was worked on elsewhere, both convergence IC's were replaced, & E995, E996, as well as IK04, & IK05. D910, & D9110 12 volt zener diodes shorted, C707 near the flyback, & horizontal output are fine, the SMPS just won't oscillate! The three opto couplers check ok, as well as the SMPS electrolytics! Ideas anyone? Thanks, Dani.



How does the pulse look did you check peak to peak & freq

Join the Discussion

Have something to add? Share your thoughts — no account required.

Didn't find your answer?

Ask the community — no account required