I want to replace blown fuse (12V, 4A) that looks like resistor, but the store only has (250V,4A) glass one, is it safe to use that?
BTW, the schematics says the line with fuse on it should use max 100mA, so why would they put 4A fuse there?
I want to replace blown fuse (12V, 4A) that looks like resistor, but the store only has (250V,4A) glass one, is it safe to use that?
BTW, the schematics says the line with fuse on it should use max 100mA, so why would they put 4A fuse there?
If the original was really 100 milliamps and there was a 4A fuse in there instead, someone did very wrong putting that value fuse in there. Under certain failure conditions it could even cause a fire.
There's other possibilities, like a printing error in the schematic, a silkscreen error on the board, etc.
Few pieces, and especially none that have motors, amplifiers, etc would use a fuse as small as 100 mA.
Mark Z.
the schematics does not say what type of fuse it is. Its a RGB port of computer and all that schematics say is that one shouldn't connect anything wanting more than 100mA on that port and that its F5 labeled fuse. When I opened case and looked at fuse and searched net, I found out that fuse should be 4A.
I don't think so. :)
--- sam | Sci.Electronics.Repair FAQ Mirror:
Note: These links are hopefully temporary until we can sort out the excessive traffic on Repairfaq.org.
Important: Anything sent to the email address in the message header above is ignored unless my full name is included in the subject line. Or, you can contact me via the Feedback Form in the FAQs.
It's ok to use a higher voltage fuse. The fuse voltage is the maximum voltage the fuse is guaranteed to be able to interrupt when it blows. Andy Cuffe
snipped-for-privacy@psu.edu
ElectronDepot website is not affiliated with any of the manufacturers or service providers discussed here. All logos and trade names are the property of their respective owners.