Er - how do you do that in the US? You don't have ring mains, so you don't have two wires.

d

In message , Arny Krueger writes

It's 2.5 square mm in area I believe, not the diameter of the core.

Chris Morriss

That is the only reason?

*If PROGRESS is for advancement, what does that make CONGRESS mean? Dave Plowman dave@davenoise.co.uk London SW To e-mail, change noise into sound.

How are sockets connected on a radial circuit? Separate terminals for in and out?

*Why do overlook and oversee mean opposite things? * Dave Plowman dave@davenoise.co.uk London SW To e-mail, change noise into sound.

My fault for not stating it was the cross sectional area. But then our US cousins quote gauge as if there was only the one. ;-)

2.5mm² equates to 13 AWG, IIRC. That is the cable normally used for UK rings, protected by a 32 amp MCB

Lighting radials are normally 1mm² which would be 17 AWG, protected by a 6 amp MCB.

*The fact that no one understands you doesn't mean you're an artist Dave Plowman dave@davenoise.co.uk London SW To e-mail, change noise into sound.

1.5mm² which is 15 AWG. My lighting breakers are rated 5A. d

1.0sqmm is perfectly acceptable for lighting circuits, BS7671 rates it at between 8A and 16A depending on the installation method. MCBs for domestic use have been "harmonised" to 6, 16, 20, 32, 40 or 63A.

David.

It all looks a bit new, maybe the installation isn't finished yet?

R

Unless you have unusually long cable runs or other special factors, it's oversized.

*Bigamy is having one wife too many - monogamy is the same Dave Plowman dave@davenoise.co.uk London SW To e-mail, change noise into sound.

When I did my rewire I was offered both 1.5mm and 1mm at pretty much the same price - certainly within about five quid for 100 metres. That made it a no-brainer.

d

Do you ever think, before posting? Someone adds another circuit, and is too cheap to buy another breaker. Or the box is full, and they won't upgrade.

You can't have a sense of humor, if you have no sense.

Isn't it enough in those places? New subdivisions are bulldozed, and if necessary, they use explosives to break up big rocks so they can be removed. You can't do that in existing neighborhoods without blowing out windows and sometimes closing busy roads for days. A lot of the above ground service areas were wired after the homes were built, and early poles were set with a pickax or jackhammer to chip away the rocks. The actual city of Cincinnati is built on 'seven hills', of mostly glacier droppings from a long gone ice age. A lot of the suburbs are of similar conditions.

The RIP process is simple: You cut the old pole near the ground and drag it off the base. You winch it out of the hole, and set the new pole in the existing hole. Then transfer the wires to the new pole. This can be done without closing most roads. Have you ever worked in utilities or even CATV construction? It doesn't look that way from here.

If you don't like the way overhead cables look, just stop staring at the sky. :)

You can't have a sense of humor, if you have no sense.

Yes. How else would they do it, if you can't use two wires under one screw?

The green screw on the lower left is for the 'Ground' connection. The silver colored screws on the left side are 'Neutral', and the brass colored screws on the right side are 'Line'.

You can't have a sense of humor, if you have no sense.

How was he able to take the picture, if the building wasn't open to the public? :)

You can't have a sense of humor, if you have no sense.

That is adding a second circuit to a breaker - nothing to do with putting the two ends of a single ring main into the same breaker terminal. Obviously it would be illegal, but it isn't what we were talking about.

So yes, I do think before posting. I thought you were stating that putting two wire ends into one terminal was illegal. It isn't. Try being a little clearer next time, will you?

d

What is wrong with having two circuits on the one breaker - provided the breaker is correctly sized for the cable? In practice it's no different from daisy chaining sockets.

*The severity of the itch is proportional to the reach * Dave Plowman dave@davenoise.co.uk London SW To e-mail, change noise into sound.

Looks like the sort of thing you'd see in the UK from before WW2. From the cheapest of makers.

I wouldn't have believed that sort of screw connection was still in use. It's a dreadful way of making a connection. Unless you first crimp on a suitable terminal.

*Why is a boxing ring square? Dave Plowman dave@davenoise.co.uk London SW To e-mail, change noise into sound.

Sounds similar to what we call a 'Baby Belling':

formatting link

Terry

Jesus, those terminals are a fire waiting to happen. They don't grip wires - all that happens when you tighten them is that the wire gets spewed out the sides. If you are lucky a tiny bit of it may still be under the screw head.

d

Maybe not where you are, but it illegal in the US as I've explained in another post.

You can't have a sense of humor, if you have no sense.