Attn Fred Bloggs I have redesigned my Binford 7000 light controller

As you can see in these images.

Sheet One.

formatting link

On this shhet I am still using the 2.45760MHZ clock osc. U1.

U3 That is marcked as "U" is my 60HZ duty cycle at 50%. This is used t = time the 273 as a ADC.=20

U7 first ouput PIN 1 from the LDR is or gated to the master reset. and = so is the power on reset.

U4 and U5 is a 120 count duty cyle I hope taking into the fact that = binary is base 2 1/0=20 This should give me a main 1HZ as indicated.

U5 and U6 are paired to together for a 120 count X2 should give me a 30 = minute duty cycle.

I took your advice and ored the Master Reset and the Delay 4017 together = to remove the randomness from the five hour delay. Everything comes out = reset at the same time when the LDR is below it's set point. The 74LS21 = Can and will be replaced with 4082 gate.

Sheet Two.

formatting link

Uses the main frequency of 2.45760 MHZ to advance my electromachinical = totaliser. Through Q1. D5 sould be in parallel with the EM totalser. I = will correct this and you will see the change. The 74LS21 is being = replaced with a 4082 gate.

Sheet Three.

formatting link

Is ment to drive the solid state realys and some panel LEDs. They are as = reverced Express PCB is well aware of this they are patching the = problem. I will be putting low current incandesant panel lights in = parallel with the solid state relays +/- controll pins to make blink = light up and flash even more.

PS. I don't why this is everything a man sees has to blink light up and = flash even when we build it. Weman. just stand their shanking their = heads saying "That's nice dear... It's got pretty lights dear." =20

--=20 My cat Tigger says every morning... "Before my morning coffee... I might as well be a dog!" To contact follow the link below.

formatting link

Reply to
Scott Wiper
Loading thread data ...

Maybe a slight arithmetic error here: U2 Q14 outputs

2.457600MHz/(2^14)=150Hz, the 4017 Cout divides by 10 for 15Hz and not 60Hz. Then the RLY A DRV holds all the counters in reset so that U8 LS273 loses its CLK and can no longer sample the LDR comparator output- the circuit is frozen. The RLY A DRV should only reset U6 and U9, and allow the 1Hz clock counters to free run to free-run. And since U13 on sheet B produces a clean 1Hz, this should be used on the sheet A for the "main 1Hz" and eliminate the 1Hz counters on sheet A.

the 273 as a ADC.

the power on reset.

base 2 1/0

duty cycle.

remove the randomness from the five hour delay. Everything comes out reset at the same time when the LDR is below it's set point. The 74LS21 Can and will be replaced with 4082 gate.

That circuit is excellent! It should work great-

totaliser. Through Q1. D5 sould be in parallel with the EM totalser. I will correct this and you will see the change. The 74LS21 is being replaced with a

4082 gate.

reverced Express PCB is well aware of this they are patching the problem. I will be putting low current incandesant panel lights in parallel with the solid state relays +/- controll pins to make blink light up and flash even more.

even when we build it. Weman. just stand their shanking their heads saying "That's nice dear... It's got pretty lights dear."