Is there a flash adc with a plcc package, anything above 24MHz minimum sample rate will suit me. tnx
Need flash adc with plcc format?
Nov 01, 2006
6 Replies
You know this is comp.arch.fpga, right? ;-)
Anyway, go search for yourself :-
formatting link
I doubt anyone would make a high speed ADC in a PLCC package, this type of package has awful SI properties.
HTH, Syms.
Is there a good reference for the types of IC packages and their effects on SI?
---Matthew Hicks
Hi Matthew, The Amkor website is somewhere to start. For example compare and contrast these two packages:-
formatting link
and
formatting link
MLF12 lead inductance ~0.6nH capacitance ~0.2pF
PLCC20 lead inductance ~2nH capacitance ~0.6pF
HTH, Syms.
Good, now what is SI ? is it shorthand for silicon? or is it the si units of measurements.
Thanks for the links Symo, I was hoping for some rules of thumb, but I guess I could look at a few datasheets of different packages and create my own. SI stands for signal integrity.
---Matthew Hicks
you posted in the wrong branch!!