FPGA DDR controller - CKE signal... do I need a pull down?

Hi guys,

I've written a DDR controller, runs on a virtex2 and interfaces a sodimm

256MB.

I've got a problem initialisating a DDR, it works 10 out of 11 times (random tbh, but fails once in a blue moon). I am not sure what it could be as I am doing all that the JEDEC specs during the initialization process... with the EXCEPTION of holding CKE low during power-up. I can NOT control the value of that signal during power-up because the FPGA has not been programmed yet (it's programmed from Flash). And there is not external pull-down.

The JEDEC standard for DDR specs that:

"Except for CKE, inputs are not recognized as valid until after VREF is applied. CKE is anSSTL_2 input, but will detect an LVCMOS LOW level after VDD is applied. Maintaining an LVCMOS LOW level on CKE during power--up is required to guarantee that the DQ andDQS outputs will be in the High--Z state, where they will remain until driven in normal operation (by a read access). After all power supply and reference voltages are stable, and the clock is stable, the DDR SDRAM requires a 200 µs delay prior to applying an executable command."

They recommend that:

"Operation or timing that is not specified is illegal and after such an event, in order to guarantee proper operation, the DRAM must be powered down and then restarted through the specified initialization sequence before normal operation can continue."

So... when the FPGA is not programmed the DDR control signals are floating, they could mimic a DDR access and put the DDR into an odd state, is that correct? If so, what do they mean by "DRAM must be powered down and then restarted...", do they mean a CKE high to low transition which in theory puts the DDR into power down mode...?

Any help would be appreciatted, thanks in advance,

--
Ignacio Ulilses Hernandez
" I'm not normally a praying man, but if you're up there, please save me, 
Superman!" - Homer Simpson ;O)
Reply to
I. Ulises Hernandez
Loading thread data ...

Hi, Put a pull-down on CKE pin that would make CKE low when power is up and DONE pin of FPGA is low.

That will make sure that there are no unstable conditions for the DDR chip.

Weng