oscilloscope problems

Mar 16, 2005 4 Replies

Hello everyone, My oscilloscope has gone wrong. Was going fine then it suddenly went out of focus for no reason. The focus knob hardly has an effect, its majorly out of focus


any ideas ?



many thanks!


Make sure it's not just HF noise that looks like defocussing.

The e-mail address in our reply-to line is reversed in an attempt to minimize spam. Our true address is of the form che...@prodigy.net.

Thanks for the replies, the model is:

Iwatsu - SS 7636 350Mhz 4 channel

Its not the leads-the whole display is like it (including the numerical display for 'time div' etc.)

As for when it happens...it was fine until the other day, and when it was on it suddenly went like it. ever since its been the same.

thanks!

Sounds like it's probably the HV/focus section (never seeing an Iwatsu myself). Got a user or service manual with a schematic & voltage test points? You might just get away with inspecting the electrolytics for leaking goo/browned/stretched plastic covering & replacing them. Check for any overheated (browned /charred) resistors, & maybe any overheated/lifted/cracked traces on the board.

***Be very, very careful with the anode lead/HV section though!!*** If it's too expensive to fix, Ebay it like everyone else! ;-) G'Luck!

Join the Discussion

Have something to add? Share your thoughts — no account required.

Didn't find your answer?

Ask the community — no account required