PALCE & GAL Devices

I have been led to believe tha PALCE devices are fuse (and everything else!) compatable with GAL devices.

Is this correct?

More specifically, can a JEDEC file aimed at a Cypress PALCE20V8 be programmed into a Lattice GAL20V8 without modification?

Thanks in advance,

Gary Partis

Reply to
partis
Loading thread data ...

"partis" schrieb im Newsbeitrag news: snipped-for-privacy@g43g2000cwa.googlegroups.com...

as much as I recall you are correct. we used PALCE and GAL in the same design with the same JEDEC file. the actual programming algorithm is different but otherwise they should be compatible

Antti

Reply to
Antti Lukats

My device programmer shows 2706 fuse counts in all Atmel ATF20V8, lattice GAL20V8, and PALCE20V8 devices. Have you tried it yet ?

-jg

Reply to
Jim Granville

Probably. I do have vague memories of some AMD PALCE devices having differing fuse counts to the corresponding GAL, but GAL files still working. If the fuse count is the same then it is pretty likely they are compatible.

Reply to
Mike Harrison

  1. partis Jul 28, 12:19 pm show options Newsgroups: comp.arch.embedded From: "partis" - Find messages by this author Date: 28 Jul 2005 12:19:34 -0700 Local: Thurs, Jul 28 2005 12:19 pm Subject: PALCE & GAL Devices Reply | Reply to Author | Forward | Print | Individual Message | Show original | Report Abuse

I have been led to believe tha PALCE devices are fuse (and everything else!) compatable with GAL devices.

Is this correct?

Reply to
StephensDigital

Thanks for all the comments. The JEDEC file created for a Cypress PALCE20V8 appears to work perfectly in a Lattice GAL20V8. :-)

Cheers

Reply to
partis

ElectronDepot website is not affiliated with any of the manufacturers or service providers discussed here. All logos and trade names are the property of their respective owners.