MPC850 - Intermittent Machine Check Exception

Jul 21, 2003 1 Replies

Has anyone had any experience with intermittent machine check exceptions on the MPC850 ? According to the MPC850's registers it fails on one particular instruction fetch (to SDRAM using UPMA) which is called by a branch instruction However our test equipment shows that it never gets to this instruction fetch as there is a phantom attempted transfer on the bus with a non existent address and a TS* issued but no chip selects ? this phantom transfer times out after the bus monitor time due to no TA* - causing a machine check



Note that this code usually runs fine and only fails occasionally



I've checked through the Chip Errata but can't find anything that relates to this problem



Anyone got any ideas or know what could be causing the phantom transfers



Thanks in anticipation Dave P.


I'm still pretty new to this but what about the watchdog timer and bus monitor? Those my not cause the machine check exceptions but I thought I would just through this out since I had problems with these.

Wayne