istina 310 V,ja priznam gresku,za to i je ova grupa! ali ne mijenja bitno,covijek se zeli zastititi,a ovaj ga odgovara od toga. "Nije po zakonu"
"Mladenc" je napisao u poruci interesnoj grupi:jagvlo$3to$ snipped-for-privacy@ss408.t-com.hr...
istina 310 V,ja priznam gresku,za to i je ova grupa! ali ne mijenja bitno,covijek se zeli zastititi,a ovaj ga odgovara od toga. "Nije po zakonu"
"Mladenc" je napisao u poruci interesnoj grupi:jagvlo$3to$ snipped-for-privacy@ss408.t-com.hr...
On Tue, 22 Nov 2011 13:17:02 +0100, -Rio- wro= te:
to =
"Puno previ=B9e" je besmislica! Nije to pravopis nego ja ne mogu ne reagirati kad netko govori/pi=B9e "p= uno =
previ=B9e", "U=BEasno dobro" i sl. jezi=E8ne gluposti. A da se nema po =E8emu drugome, ima, i bilo je upravo po tome drugome.
-- http://www.refrigeration-engineer.com http://fanzo.org/forum/
Nije ZUSP nego ZUDS (za¹titni ureðaj diferencijalne struje)... malo disleksija ili kaj?
Nije ba¹... a i da je, propisi (bar kaj se tice sigurnosti el. instalacija) dolaze iz struke i postoje razlozi zasto ih treba koristiti i shvatiti ozbiljno... Evo jedna paralela... "mo¾e¹ se po zimi voziti s celavim ljetnim gumama ili montirati drvene kotace, ali je samo pitanje koliki ti je zaustavni put..."
Ne mo?e.
Mjeri razliku struja.
Ne. Tu treba? za?titu od direktnog dodira (izoliranje, ugra?ivanje, ogra?ivanje, udaljavanje). FID sklopka ?titi od indirektnog dodira. Npr. ako bi dotaknuo neispravan ure?aj FID sklopka bi isklopila napajanje.
Deèec dragi, ti si se sa strukom i zdravim razumom odavno razi¹el. Gluposti koje si napisal nemaju ni v riti mesta, a kamoli v struci!!!
Pozdrav!
Tomy, 9A5ALL
Bez mjesanja tko je u pravu vise ili manje a tko nije, osobno bih najprije procitatao nesto ovako:
a kod izrade ili repariranja instalacija, informirao se o ostalim zastitnim uredajima:
Ne mora biti Schneider, ali ovo mi je prvo naletilo pod google.
Kuki
;) Deèec, ili krivo kvota¹ ili si se na krivog nameril ili ... no, nebitno...
Ni¹t krivo ne kvotam, niti sam se na krivog nameril. Nameril sam sem na nekog kog blati MOJU struku, i dela se pameten med onima koji oèito znaju razmi¹ljati (nije da su 100% u pravu, al se ne pozivaju na "struku").
Oèito je da dela¹ posel koji dela¹, al oèito je takoðer da nezna¹ ZAKAJ tak dela¹.
Pozdrav!
Tomy, 9A5ALL
Mo?e se koristiti, ali ne?e u potpunosti izvr?avati svoju funkciju. No, bolje imati nekakvu za?titu nego nikakvu. Savjetuje se promjena el. instalacije, ugradnja 3-?ilnog kabla s za?titnim vodi?em (uzemljenje).
Upravo to je i ?ovjek napisao, ali slikovito. :)
To?no je to ?to si napisao, ali on je vjerujem opet slikovito pitao ?to bi bilo kad bi se uhvatio za fazu. Pri tome "uhvatiti za fazu" ne zna?i doslovno otvoriti razvodni ormar i namjerno se uhvatiti za fazu, nego eto, ne?to je do?lo u kontakt s fazom uslijed kvara, pa se ?rtva na neki na?in uhvati za to. Kratko je napisao "primi za fazu".
Samo ?ovjek koji ima suicidne namjere ide svjesno primiti se za fazu. :)
Za one koji su se ukljuèili u raspravu i misle da FID (RCD) nije za¹tita od direktnog dodira, a nemaju vremena proèitati tekst sa gornjih linkova - evo ¹to o tome ka¾e renomirani proizvoðaè fidovki: "dodatna za¹tita od direktnog dodira". Ne¹to kao rezervni padobran - dobro je imati glavni, ali i rezervni je spasio puno ¾ivota iako je doskok puno tvrði. A u nu¾di (stara dvo¾ilna instalacija i sliène situacije) bolje je skoèiti i samo sa rezervnim padobranom (FID bez uzemljenja) nego bez njega (dvo¾ilna instalacije bez FID).
4.2 ApplicationsAdditional protection against direct contacts
An RCD can detect low leakage currents that
could flow through the body of a person. It thus
provides additional protection if the normal
protection means fail, e.g. old or damaged
insulation, human error, etc. This can also be
referred to as ultimate protection because it can
interrupt the current even if the other devices
have failed.
Use of a 30 mA RCD on all circuits supplying
socket-outlets up to 20 A is now mandatory, as
per IEC 60364-4-41, Electrical installations in
buildings, Protection for safety - Protection
against electric shock.
Note that an RCD does not limit the
instantaneous current flowing through the body,
but does limit the time the current flows. Note
also that for a direct contact with a 230 V phase
conductor, the flowing current would be
approximately 150 mA. RCDs with 10 or 30 mA
sensitivities let the same current through.
The two sensitivities provide equivalent
protection. However, the 30 mA threshold
provides a cost-effective compromise between
safety and continuity of service.
Ma kakvi renomirani proizvodjaci? Nemru oni znat vise od zakona u NN i ljudi tipa "©to struka, ¹to se vec 15 godina bavim ispitivanjima, projektiranjem i nadzorom el. instalacija i postrojenja... " :) jao si ga nama sa nasim "strucnjacima"
zaboravih
DZ hvala ti na ovoj tocki na i. Mislim da su i nasi "strucnjaci" ovde naucili vise nego sto su znali a i svi mi ostali. Svatko tko je procitao cijeli ovaj thread i ima dovoljno soli u glavi da razluci informacije od dezinformacija moze zakljuciti da je FID sklopka uglavnom demistificirana.
Hvala ti za "hvala", èastim sa èevapima i pivom ako se kad sretnemo :)
On 26 stu, 15:58, "Paky" wrote: Mislim da su i nasi "strucnjaci" ovde
.Nakon 68 komentara, "nau=E8ili" smo da se FID-ovka mo=BEe koristiti i bez tre=E6eg vodi=E8a u instalaciji (uzemljenja)... Aparat je pod naponom, i =E8eka =BErtvu, kojoj je najbolje da gola sjedi u punoj kadi vode. Na taj na=E8in bit =E6e ostvaren najmanji mogu=E6i prijelazni otpor, za struju koj= a =E6e (jednog dana) mo=BEda izbaciti FID-ovku.
Nekim =E8udom, po propisima struke (koji JEDNAKO vrijede i u Hrvatskoj, i u Njema=E8koj i ostaku EU), osim mjera obaveznog za=B9titnog uzemljenja i izjedna=E8avanja potencijala, za mokre-sanitarne =E8vorove obvezna je dodatna FID sklopka osjetljivosti 30 mA, umjesto "klasi=E8ne" od 400 ili
500 mA.Fid na dvozilnoj instalaciji hmm zasta onda osiguraci sluze a Fid moze pomo ci u slucaju dodirnog napona iako se nebi htjeo naci u takvoj situaciji..Ra dim vec 20 god i Fid sklopka je zastita uobicajena bilo da kuca,stan ima vl astito uzemljenje ili nulovano u trafo stanici ili ti ga u ormaru..nulu pri je fida na uzemljenje,poslije fida nula na N sabirnicu i bila stvar..
Na pravilnom uzemljenju nebi se smjelo to desavat samo izmedzu faze i uzemljenja da reaguje Fid po ps a izmedzu L i N ima osigurac za to..jednostavno
Od kuda si sve ovo prevodio pomocu googlica!?:-)
Osiguraci su dobri jer ce recimo 10A izbaciti cim struja u toj grani prede tu vrijednost, inace bi fidovka izbacila tek pri 30-40-50A. Osim toga, kada vidis koji osigurac je izbacio, lakse je naci kvar, ne moras kopati po cijeloj instalaciji!.....
nda slijedi:fid sklopku ne zanima kako je ostvarena razlika struje ,preko u