Voltage spike protection

Imagine a device working at 1 Volt.

I what to protect it from a voltage spike of 50 to 100 Volts.

Does any know how to do this in a cheap way???

Efthimios

Reply to
Efthimios
Loading thread data ...

You'll need to define your requirements for "protect." No over-voltage protection can react in zero time to clamp the voltage to (V-limit plus exactly 0 volts).

Knowing how to do it cheaply requires more knowledge of what device and in what environment. Guessing the operating and maximum allowable parameters of an arbitrary device isn't productive.

--
Rich Webb     Norfolk, VA
Reply to
Rich Webb

"Efthimios" skrev i meddelelsen news: snipped-for-privacy@3g2000yqs.googlegroups.com...

limit the current into the device to a safe value

Reply to
Frithiof Jensen

-The spike has a duration of 0.2 to 0.3 seconds.

-The device to be protected is a sensor with operation voltage of 1 Volt and maximum allowed 1.5 Volts.

-The sensor draws a less than 0.1 milliamp.

-The device works under normal room temperature and humidity conditions

-Cost preferably about a dollar.

Reply to
Efthimios

Yes, but we frown on doing people's homework for them. Maybe check the other side of google for "transient protection" or so.

Good Luck! Rich

Reply to
Rich Grise

Protection of power rails and signal lines pose differing problems. You'd have to be more specific about the actual node on the specific device that was threatened.

RL

Reply to
legg

"Efthimios"

-The spike has a duration of 0.2 to 0.3 seconds.

-The device to be protected is a sensor with operation voltage of 1 Volt and maximum allowed 1.5 Volts.

-The sensor draws a less than 0.1 milliamp.

-The device works under normal room temperature and humidity conditions

-Cost preferably about a dollar.

** Use a bridge rectifier.

Just short the + and - terminals together and connect the AC ones across your sensor - this will clamp the DC rail to 1.5 vols. A 1 or 2 amp rated bridge costs about $1 ( DIL ones are cheapest ) and will survive 5 amps or more for 0.3 seconds.

Your problem if there is no series impedance limiting the current to a few amps.

..... Phil

Reply to
Phil Allison

---+---[DEVICE]-+---[fuse]--- | | +-->|--->|---+ | | +--|

Reply to
Jasen Betts

So, you need to put a network between the source and the sensor that passes 1V and 0.1 milliamp accurately (so less than 10 mV drop and less than 1 uA current error), but protects a sensor that undergoes some kind of failure at 1.5V, against inputs in the 100V range.

Is that +100V? or could it be -100V?

Usually, one would put a triggerable shunt across the sensor, and a small triac (or pair of SCRs) might do it. Most packaged surge protectors operate at much higher voltages, though, and sense-with-an-amplifier schemes have a few microseconds of delay.

Reply to
whit3rd

If 1.5 volt is the max allowed, why not use the simple components that are out there already? 2 sets of diodes to form 1.5 average break down joined back to back.

this gives you a nice bi-directional clamp via some components that should be able to handle that through some kind of current limiting source, like a resistor.

They also make TVS diodes...

formatting link
"

Reply to
Jamie

ElectronDepot website is not affiliated with any of the manufacturers or service providers discussed here. All logos and trade names are the property of their respective owners.