Scientists builld a nuclear clock that could make atomic clocks obsolete

Oct 11, 2026 Last reply: 1 month ago 84 Replies
Jump to replies (84)

From:

formatting link
Scientists build a nuclear clock that could make atomic clocks obsolete Researchers in Vienna have built the world’s first self-stabilizing nuclear clock, bringing scientists closer to a new era of ultra-precise timekeeping. Date: October 10, 2026 Source: Vienna University of Technology Summary: Scientists in Vienna have achieved a major breakthrough in timekeeping by creating the world’s first self-stabilizing nuclear clock, a technology that could eventually surpass even the most precise atomic clocks. Instead of relying on electrons in atoms, the clock uses the tiny nuclei of thorium atoms, which are far less sensitive to outside disturbances.


Mmh. They state an error of one second in 30M years. That's a relative error of 1e-15. I was convinced that the state-of- the-art atomic clocks were in the 1e-18 ballpark. This new clock will only have to get more than a thousand times better then.

Jeroen Belleman

The science daily article does make the point that the researchers have got the system to a point where it works, rather than to the point where it works as well as it could.

"The researchers believe their nuclear clock has considerable room for improvement. By using more powerful lasers and developing higher-quality thorium crystals, they hope to substantially increase its precision."

The thorium nucleus is a very high-Q resonator, but if you can keep the nuclei in a particularly stable environment, and latch precisely onto the peak of the resonance, you can use it to constrain oscillation frequency particularly tightly.

Ah! Well I will stick to my Rubidium reference and my DFC77 clock and Casio radio watch to check the doomsday clock against. That seems to be stuck near 12 o'clock

formatting link
The sciencedaily write-up did mention that the authors expected to do better.

The wikipedia article does include a lot of discussion of ways in which they could do better.

Just wait until somebody figures out a way to use Mössbauer's discovery of the exceedingly narrow resonances in Iron-57.

Cesium-133 has a resonance at 9.1GHz, Thorium-229 at 2PHz, and Iron-57 at 3.5EHz. That's RF, UV and gamma, respectively. We don't know yet how to excite that last resonance, except by making more Iron-57.

Jeroen Belleman

Like the Pound–Rebka Experiment (1959–1960)?

formatting link

Pound and Rebeka seem to have used a Co-57 source to get their gamma rays. Co-57 isn't stable and decays to an excited form of Fe-57 (which is stable) but emits the nice narrow 14.4 keV gamma rays during the decay process.

That's what I meant by "making more Iron-57". 14.4 keV = 3.5 EHz.

Could Fe-57 be made to 'lase' (gase?) if we excite it with enough

139 keV gamma radiation? Probably not.

(GASER: Gamma Amplification by Stimulated Emission of Radiation. You saw it here first.)

Jeroen Belleman

It wasn't exactly spelled out.

formatting link
uses a synchrotron light source to produce 14.4 keV gamma rays within a bandwidth of 15 neV which are tunable in energy over a range of about ±0.6 µeV

Who needs a gaser?

Sure did. Everyone else calls it a GRASER. ;)

formatting link

You can’t make mirrors for gammas, so it would be amplified spontaneous emission, as in the masers occurring in molecular clouds.

Clockmaking is at the point of becoming a cultural activity like space travel and string theory.

Cheers

Phil Hobbs

How do you divide the laser frequency down to 1 Hz?

Interesting, thank you. I found some names of people I've met with over the years in the reference list, even though I wasn't involved in synchrotron light sources.

Not sure if this is useful to create extremely accurate clocks. You'd need a coherent source for that. Also, using a synchrotron light source to make a clock is, well, shocking.

Jeroen Belleman

Well, Hänsch, Hall and Glauber invented the 'optical frequency comb', which can be used to translate the UV resonance of Th-229 down to lower frequencies until you reach something that electronics can handle.

They won the 2005 physics Nobel prize for that work. Well deserved, I think.

Jeroen Belleman

Now not super difficult, ever since Jan Hall and Ted Hänsch invented the locked comb generator. (They’re both acquaintances of mine, in different eras.)

You take a modelocked Ti:sapph laser, use a holey fiber to broaden the spectrum to a full octave, then offset-lock a line at the blue end to the second harmonic of one at the red end.

The offset comes from a cesium standard, which in principle gives each line of the comb the same absolute accuracy as the standard.

You do have to measure the comb spacing accurately enough that you know exactly how many teeth are in an octave, but using one of those, you can heterodyne an unknown signal down to baseboard and measure the delta with a counter.

You need a good enough SNR that you don’t skip cycles, but that turns out to be quite practical.

Cheers

Phil Hobbs

You can make grazing incidence mirrors for X-rays.

formatting link
Gamma rays might be more difficult.

Gravitational lenses might work, but we lack a source of mini black holes (and they wouldn't be expected to last all that long if we could create them).

It might be fun to accelerate positive and negative U-238 ions in the same cyclotron. At some point the point masses passing one another at close to the speed of light might generate enough gravitational radiation to prevent further acceleration, but then again they might collide to create very small black holes (though that seems unlikely).

Not the first time you've asked this question. Happily the answers remain the same.

When I was a kid we had nuclear clocks.

Which is also right twice a day. ;)

Cheers

Phil Hobbs

Within picoseconds.

Dark-adapted, you could see individual alpha flashes.

John Larkin Highland Tech Glen Canyon Design Center Lunatic Fringe Electronics

So you were referring to a clock with radioactive paint on the hands and the dial so you could see them both in the middle of the night without having to turn any lights on.

People were less worried about cancer-inducing mutations back then.

I remember seeing the bones of my feet in a shoe-store fluoroscope.

Join the Discussion

Have something to add? Share your thoughts — no account required.

Didn't find your answer?

Ask the community — no account required