You've obviously not had much experience of repairing old valve equiment.
You've obviously not had much experience of repairing old valve equiment.
I cetainly could. And it would make whacking big pulses into a PMT.
And I can see a good LED at 1 nA.
Is it an antique? I don't think people sell radium-phosphor things any more.
There's a decommissioned shipyard near here, and aircraft carriers used to have hockey-puck sized nuclear deck lights. They turn up in the dirt now and then. I want one.
The shoe-store things didn't use electrons. They used x-rays.
John Larkin Highland Tech Glen Canyon Design Center Lunatic Fringe Electronics
You always prefer to call people stupid rather than learnng anything yourself.
First hit on ebay:
Stop being nasty and lazy. Learn how to discuss and learn how to do web searches.
John Larkin Highland Tech Glen Canyon Design Center Lunatic Fringe Electronics
Last week I even had to throw away a SDcard adaptor for a micro-sdcard for in my old Raspberry Pi, contacts damaged, intermittent, caused a crash.
Any mechanical contact can go bad. In my grass mower it caused it to stop working altogether. bit of WD40 brought it back to life Have not tried WD40 on tube sockets and SDcards though, but it IS miracle stuff.
John Lark> I cetainly could.
So could I (not the alpha itself but the flash it produced striking the zinc sulfide phosphor). I don't think people sell radium-phosphor things any more.
They use tritium.
I also remember seeing the flashes on a watch I owned as a child.
Or the strontium alunimate stuff.
John Larkin Highland Tech Glen Canyon Design Center Lunatic Fringe Electronics
Many animals can see single photons, but that's borderline in humans. Humans can reliably see 10 or so.
A radium alpha is around 5 MEV, and a green photon is around 2 EV, so seeing a flash is not unreasonable, except that certain experts here have declared it to be impossible.
John Larkin Highland Tech Glen Canyon Design Center Lunatic Fringe Electronics
That's phosphorescence. Goes dark after six hours or so until it is recharged by bright light. No radioactives involved.
Den 18.10.2026 17:00, skrev john larkin:
No, it's not antique and it is not radium but tritium, an isotope of hydrogen with two neutrons. It decays to helium when a neutron splits into one proton and an electron.
These watches are still quite common.
I knew that.
John Larkin Highland Tech Glen Canyon Design Center Lunatic Fringe Electronics
The old ones were radium and zinc sulfide.
We put a couple on bedposts in the cabin, so we don't whack them in the dark.
John Larkin Highland Tech Glen Canyon Design Center Lunatic Fringe Electronics
Yes I have those too:
But the glass and the metal aren't going to be at the same temperature when you solder something onto the pin.
True. Modern stuff tends to become obsolete before it has had a chance to rust/oxidise/corrode, and we now have larger range of contact alloys to chose from.
My first ever published comment was a on photomultipler tubes in 1972. It turns out that it was also my first publication to get cited. I was still working with them in 1991.
You don't know how that was assembled and "learning" stuff From what you can find on ebay isn't a good way of getting instructed.
You need the gas flames to make the tubes. I've put tungsten pins into borosilicate glass from to time. You need to anneal the assembly fairly carefully if you want it to cool down without breaking, even though tungsten's coefficient of expansion is a pretty good match to that of borosilicate glass.
Your faith in your own web-searching skills is misplaced. It's not lazy to skip doing something pointless, and while it may be nasty to point out where others have screwed up, it's not wise to let half-wits spread bad ideas without criticism.
The shoe sales people didn't have to put their own feet on the machines.
Use lead glass above the screen that is getting hit by the X-rays and shield the source, and you shouldn't zap anybody except the customers, and then only their feet.
The big problem with corrosion in valveholders was variable contact resistance in a circuit carrying both DC and a low-level signal. Any small movement of the valve cause violent crashes and bangs in audio circuits.
Worse still, the heater circuit could go intermittently open-circuit and that wouldn't be spotted if the valve was inside a screening can. The symptoms were most mysterious because they disapeared for a while after you had taken the valve out to test it - found it was OK - and put it back in.
My Allen Scythe needed a complete rebuild of the ignition system - but at least there are no safety devices to go wrong.
<snip>
Not exactly well-designed equipment then.
If you insist on making a continuous metal-to-metal contact with the metal going through a glass to metal seal there are relatively safe ways of doing it.
Clamping a massive metal heat sink onto the pin between the glass to metal joint while you are making the electrical connection is useful precaution.
Spot welding the electrical connection onto the pin can happen fast enough that you only get a small smeared-out temperature surge at the glass to metal seal.
But it does pay to think about what you are doing. The metal pin is a better heat conductor that the glass it is sealed into, and if it gets hot enough fast enough it will crack the seal.
This wasn't bad design, it was universal even in the best designs because of the constraints of the components, there was no other way to do it. It is difficult (impossible?) to design valve or transistor stages without having DC and signal sharing the same path at many points. The early transistors suffered from the same connection problems when they were plugged into holders.
Some of the later professional 'high reliability' valve equipment had a meter which could be switched into each valve circuit to read the anode current or some other parameter which would help with diagnosis. The even earlier equipment had a jackfield into which an external meter could be plugged (so they only needed a single meter between all the equipment) but it meant that the operator was holding a meter with the full HT on its exposed screw terminals.
If you really do want to see some bad design, a certain "Hi-Fi" amplifier used plug-in cards with edge connectors. The circuit of the thermal bias compensator ran through two of those connections and when they became corroded, both output transistors passed maximum current and shorted the power supply.
Have something to add? Share your thoughts — no account required.
Ask the community — no account required