Scientists builld a nuclear clock that could make atomic clocks obsolete

Oct 11, 2026 Last reply: 1 month ago 84 Replies

Astronouts on the ISS experience that.

Yes, that was fun and scary at the same time.

Gerhard

I doubt that the glowing clocks or the shoe x-ray were any serious hazard to consumers.

My dentist does a *lot* of xrays now, but the detector sensitivity is probably much better than the old film system so I expect the radiation dose is low.

The glowing clocks were famously hazardous to the girls who put the paint on the hands and the dials - they were told to lick the tips of their paint bushes to the fine point that the job needed, and a lot of them developed mouth cancers.

formatting link

It's too late for elderly patients like you. They should be more careful with kids.

I said "to consumers."

I doubt that any radiation was measurable outside of the clocks.

Tooth decay has its own health hazards.

John Larkin Highland Tech Glen Canyon Design Center Lunatic Fringe Electronics

I think those machines used a Rhumkorff coill to generate the high voltage.

For a fluoroscope to be visible in that rig the xray flux must have been huge. The shoe sales people got zapped hard.

Radium produces a mixture of alpha, beta and gamma radiation. The alpha will not escape. Much of the beta will probably get through the glass and nearly all of the gamma will pass through the glass and metal parts. Definitely detectable. John

Most sources say that radium dial clocks are not hazardous if unbroken.

Many in an unventilated space can build up radon.

Not killing off consumers is a virtue, but it doesn't excuse killing off the people who manufactured the product.

formatting link
As usual, you haven't checked. Radon gas is one of the decay products, and some of the decays generate gamma radiation.

And low doses of fluoride ions make it much less likely. Some dental x-rays may be justifiable, even for kids, but the justiable number will increase with age.

Soft x-rays are easy to stop. A bit iron and lead glass around the source and the screen should have minimised the dose outside the machine. Whether the design was that careful isn't an easy question to answer.

formatting link
does suggest that they did include some shielding. The UK version (which is probably what I would have been exposed to) was a factor of ten less dangerous than it's US equivalent.

Indeed, and you can measure all that

formatting link
There is a good group to discus these things and experiemnts
formatting link

You *soldered* things directly to the pins of a photomultiplier tube?

Barbarian!

Jeroen Belleman

No, that PMT came with a PCB attached (cheap ebay PMT IIRC, been 16 years) so I used that resistor divider for the anode voltages and soldered to that PCB. That PMT still works fine. I use a smaller Russian PMT in my gamma spectrometer:

formatting link
as you can see I did not bother with the front button labeling, cursor move buttons are obvious and button effects are displayed on the LCD anyways. ;-)

This is in the cardboard tube, plus a scintillation crystal:

formatting link
formatting link
formatting link
the little diodes in the voltage multiplier? panteltje.nl/pub/cosmic_rays_to_crystal_to_pmt_to_darlington_to_led_low_light_mvi_3120.avi

Whole thing runs on 2 AA Eneloop rechargables. Unlike ZERN that needs more power than a small country.

There is more of course:

formatting link
formatting link
There is a lot more.. tried several scintillation crystals

All 60/40 solder of course.

He's either brave or stupid. Every pin on the base of a photomultiplier tube goes through a glass to metal seal, and heating up the pins risks breaking the glass.

More cautious people plug photomultiplier tubes into sockets, and solder the sockets into printed circuit boards (or wire them up to other components) before they plug in the tube.

The tubes can be quite big, fragile and expensive. The sockets aren't cheap either.

Barbarians are merely people who can't speak Greek, and thus ill-informed. Jan is fluent in several languages, so he's more slap-dash than ill-informed.

I have soldered thousands or tens of thousands TO-18 and TO-5 transistors with hermetic glass metal seals without glass damage. Miniature wire ended vacuum tubes didn’t have problems either.

Yes. The alloy used for vacuum tube pins is chosen to have a thermal coefficient of expansion that matches that of the glass (which is quite low).

A good reason to solder photomultiplier tube pins is to eliminate noise generated by the pin to socket contact.

It might be if the pin-to-socket contact generated any noise. Contact resistance is a fraction of an ohm - not exactly a problematic noise source.

In my gamma spectrometer:

formatting link
:-)

No, you could not! :-D

I have such a watch on my wrist right now.

My clock has ~37000 Bq (becquerels, decays per second) Most of the electrons are blocked by the watch glass and casing.

The limit set by the U.S. Nuclear Regulatory Commission for retail products is 185000 Bq.

I am not worried!

The light is made by fluoresce. When electrons hit phosphor, photons are emitted.

Join the Discussion

Have something to add? Share your thoughts — no account required.

Didn't find your answer?

Ask the community — no account required